BocaFlasher.com
2 of 7
Installation Manual
HPNFC-RT
REV 04-2019
TURN POWER OFF AT CIRCUIT BREAKER BEFORE BEGINNING INSTALLATION!
INCLUDED IN THE PACKAGE:
1. HPNFC-RT Fixtures
(In lengths shown on job
specific drawings)
2. Mounting Brackets
(2 brackets per fixture)
3. Job Specific Drawings
Power cord length is
6.5ft per UL standard
OR
OR
Fixed
3” Arc
Swivel
6” Arc
HPNFC-HO
HPNFC-RT
CAUTION: Before installing any type of clip (fixed, swivel or arc) onto the mounting surface determine
if the fixtures have rigid or twist lock connections at each end (examples of the rigid and twist lock types
are shown in section 4).
INSTALLATION OF CLIPS FOR LIGHT FIXTURES WITH RIGID CONNECTIONS:
1. Light fixtures that have rigid connections on each end must be installed in the same plane and must also be in a straight
alignment. Using a chalk line or laser, mark a line on the flat surface where the clips are to be mounted. Align each clip to the
chalk line using the same reference point on each clip (clip edge or hole) and space the clips according to the length of each
fixture (see figure A). Clip placement: Boca Flasher recommends clips to be installed 1.5” from end cap.
2. Snap in the first light fixture into the clips (see section 2, installing fixtures into clips). Snap the 2nd. light fixture into adjacent
clips ensuring that the connections will mate (male to female, see figure B).
3. Slide the second light fixture into the first light fixture until fully seated. ( see figure B & 4d).
4. Install #2 lock screw (see figure 4e).
5. CAUTION DO NOT MATE FIXTURES THAT ARE NOT IN LINE OR FORCE TOGETHER BY WIGGLING. THIS CAN CAUSE
PERMANENT DAMAGE TO FIXTURE CONNECTION AND OPERATION. ( see figure B).
6. Continue this process until all light fixtures are installed according to the job specific layout drawings.
7. Connect fixtures to power per section 5 and 6.