Rectifying faults
General operating problems
38
099-004839-BOC01
10.11.2009
7.4
General operating problems
Problem
Possible cause > remedy
Machine control without displaying the signal
lights after switching on
• Phase failure > check mains connection (fuses)
no welding performance
• Phase failure > check mains connection (fuses)
various parameters cannot be set
• Entry level is blocked > disable access lock (see
chapter entitled "key switch", if available)
7.4.1
Interface for mechanised welding
WARNING
No function of the external shut-down devices (emergency stop switch)!
If the emergency stop circuit has been realised using an external shut-down device via
the interface for mechanised welding, the device must be set for this setup. If this is not
observed, the power source will ignore the external shut-down devices and will not shut
down!
• Disconnect jumper 1 on PCB T320/1 or M320/1!