Cooling
Cooling
2.5.1 The Stokes M icrovac pump is w ater cooled and must be connected to a
w ater supply.
2.5.2 The 1/2" w ater inlet connection is located in the pump housing on the drive side
near the bottom. See Figure 7.
2.5.3 Insert a valve in the w ater inlet line and regulate the w ater flow so that the
temperature of the oil in the reservoir is betw een 140 Deg. and 160 Deg. F. (60 - 71
Deg. C) Oil temperature kits are available that automatically control the w ater flow
to maintain the proper oil temperature (Contact Stokes Vacuum for specifications).
If pump is outside and subjected to freezing temperatures, the w ater tank and
circulating pump should be installed w ith anti-freeze in the w ater.
CA U TION :
CA U TION :
DO NOT START THE PUM P WHEN O
DO NOT START THE PUM P WHEN OIL TEM PERATURE IS BELOW 55
IL TEM PERATURE IS BELOW 55
o
o
F. (13
F. (13
o
o
C)
C)
2.5.4 The 1/2" w ater outlet is located in the pump housing on the opposite side of the
w ater inlet. See Figure 7.
2.5.5 The w ater outlet SHOULD
SHOULD be connected to an open drain to permit the operator to
check the flow and temperature of the outlet w ater periodically. There SHOULD
SHOULD
NOT
NOT be a valve or back pressure in the drain line. In some cases, cooling w ater
must be discharged to a pressure drain. In such cases, discharge pressure must
not exceed 35 P.S.I.G. and no block valve should be placed in discharge line unless
a 35 lb. relief valve is provided to protect pump from high inlet pressure.
N OTE:
N OTE:
If condensables are present in gas being pumped and gas ballast is used, throttle
If condensables are present in gas being pumped and gas ballast is used, throttle the
the
cooling w ater to raise operating temperature to the level for gas ballast (See Sect. 3)
cooling w ater to raise operating temperature to the level for gas ballast (See Sect. 3)
2 .6
2 .6
Lubricat ion of Pum p
Lubricat ion of Pum p
The successful operation of this pump depends largely on the type of oil used. An initial charge of oil is included
w ith each pump. This standard oil is Stokes V-Lube (Label F) w hich is recommended for general operating
conditions in a relatively clean environment. The oil is a multigrade petroleum oil, fortified for oxidation
FIGU RE 5 A WIRIN G D IA GRA M
FIGU RE 5 A WIRIN G D IA GRA M
Summary of Contents for 212-J
Page 19: ...J SERIES M ICROVAC J SERIES M ICROVAC VACUUM PUM P VACUUM PUM P PAGE 6 2...
Page 21: ...J SERIES M ICROVAC J SERIES M ICROVAC VACUUM PUM P VACUUM PUM P PAGE 6 4...
Page 28: ......
Page 29: ......
Page 32: ......
Page 33: ......