background image

 

Back View of CS2  

Mains Cable  

Back View of Heater  

Switch link Cable - Use 
1.5mm² 4 Core Cable 
(see note above) 
  

 

5. CONNECTING A CS-2 CONTROL SWITCH TO THE HEATER

 

CS-2  control  switch  box  can  be  easily  connected  to  the  HN2-3000G Heater.  This  will  allow  the  heater  to  be  operated  with  one  or  two  lamps  so 
controlling the heat output. 

Please make sure you have read the Safety instructions and that you are a suitably qualified electrician before continuing.  

Drawings show connections inside the terminal box on the outside of the heater and the inside of the CS2 Controller.  
Please Note:- Specified cable sizes are for typical installations, correction factors may need to be used when determining actual cable sizes. 

Follow the following instructions to connect the heater to CS-2 Switch Box 

a)  Open terminal box on back of heater. 
b)  Remove blanking plug in the heater connecting box and fit cable gland to suit cable you are using (not supplied).  
c)  Remove Brown Link cable between L - L1 and L1 - L2. 
d)  Use 4 core silicon cable having a temperature rating of 180ºC or other suitable cable that will withstand 85ºC continuously. 
e)  Connect the cable as per drawings below. 
f)  Switch box CS2 MUST be earthed. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

6. CONNECTING CS-2 CONTROL SWITCH TO MULTI HEATERS

 

 

Using the CS2 switch unit 2 or more 2 Lamp Heaters may be connected as per wiring diagram below.  
If you require further technical help on multi-heater connection please contact us using the number on the back page. 

 
 
 