background image

 

 

 
 

6.3  Adding a CS-7 Controller (CS-7 Controller provides on / off / high heat / low heat / fan only settings). 
 

Please make sure you have read the Safety instructions and that you are a suitably qualified electrician before continuing.  

Drawings show connections inside the black terminal box on the outside of the air curtain and the inside of the CS-7 Controller.  

Do NOT use power tools to undo or do up terminal screws.

 

Please Note:- Specified cable sizes are for typical installations, correction factors may need to be used when determining actual 

cable sizes. 

 
 

Standard Connection using CS-7 Controller 

 

 
 
Use 0.75mm² 5 Core Cable to connect the air curtain to the CS-7 Controller (see note above). 

Remove any links 

that may be present in air curtain Control Box between terminals 1,2,3,4 or 5. 

 
 

Air curtain (Control Box) to CS-7 Controller Cable

– (Colours for reference only) 

Connect Brown wire 

– Terminal 1 or L of air curtain and Top Terminal L2 on right DP Switch of CS-7. 

Connect Grey wire 

– Terminal 2 of air curtain and Centre Switch Terminal 1 of CS-7. 

Connect Blue wire (adding red or other suitable colour sleeve to both ends first) 

– Terminal 3 of air curtain and Terminal 1 on Left SP 

Switch of CS-7. 

Connect Black wire 

– Terminal 4 of air curtain and Terminal 2 on left SP Switch of CS-7. 

Connect Green / Yellow wire 

– Terminal E or 

of air curtain and earth connection on CS-7. 

 

 

PLEASE CHECK ALL CONNECTIONS BEFORE TURNING ON AS INCORRECT WIRING IS NOT COVERED BY THE 

GUARANTEE

 

 

Summary of Contents for CAT-90

Page 1: ...an The unit should be protected by a suitably rated isolator and fuse or MCB This air curtain is IP20 rated and is suitable for indoor or under cover use only Do not attach this air curtain to an exte...

Page 2: ...2 x M5 Lock washers 4 x M4 Nuts and 4 x M4 Washers 4 2 WALL MOUNTING ABOVE A DOORWAY Attach the two Small wall mounting brackets to the air curtain using the Plastic Domes and M2 9 Screws Make sure bo...

Page 3: ...n switch back to the fuse board use 10mm cable Drawings show connections inside the black terminal box on the outside of the air curtain Do NOT use power tools to undo or do up terminal screws Please...

Page 4: ...the power supply box Use minimum 1 5mm 5 Core Mains Cable see note above Connect Brown wire Terminal 1 or L Connect Black wire Terminal 2 Connect Grey wire Terminal 3 Connect Blue wire Terminal 5 or N...

Page 5: ...low wire Terminal E or of air curtain and earth connection on Thermostat PLEASE CHECK ALL CONNECTIONS BEFORE TURNING ON AS INCORRECT WIRING IS NOT COVERED BY THE GUARANTEE 6 2 Adding a Programmable Ti...

Page 6: ...the air curtain to the CS 7 Controller see note above Remove any links that may be present in air curtain Control Box between terminals 1 2 3 4 or 5 Air curtain Control Box to CS 7 Controller Cable C...

Page 7: ...s for reference only Move the Dark Brown link cable from the centre switch terminal 1 to the centre switch terminal 3 shown above by dark brown wire Connect Brown wire Terminal 1 or L of air curtain a...

Page 8: ...gn materials around the airways If the air curtain fails to operate or the safety cut out operates again turn off the air curtain and contact a qualified electrician The Air curtain is protected by a...