background image

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Thank  you  for  purchasing  a  BN  Thermic  product.  Manufactured  to  a  high  standard,  this  product  will,  if  used  according  to  these  instructions  and 
properly maintained, give you years of trouble free performance.

 

Please ensure instructions remain with your customer for their reference. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

1 .   S AF ET Y   I N ST R U C T I O N S

 

1.1 ELECTRICAL SAFETY 

WARNING!

 It is the responsibility of the owner and the operator to read, understand and comply with the following:  

You  must  check  all  electrical  products,  before  use,  to  ensure  that  they  are  safe.  You  must  inspect  power  cables,  plugs, 
sockets and any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the 
installation  of  appropriate  safety  devices.  A  Residual  Current  Circuit  Breaker  (RCCB)  should  be  incorporated  in  the  main 
distribution board. If in any doubt consult a qualified electrician.  

You must also read and understand the following instructions concerning electrical safety. 

  The  Health  &  Safety  at Work  Act  1974  makes  owners  of  electrical  appliances  responsible  for  the  safe  condition  of  those 

appliances and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.  

  Installation  should  always  be  carried  out  by  a  qualified  electrician  or  a  competent  person  in  accordance  with  current 

electrical regulation. 

  Ensure  that  the  insulation  of  all  the  cables  on  the  appliance  is  undamaged  and  safe,  before  connecting  it  to  the  power 

supply. 

  Ensure that the cables are always protected against short circuit and overload. 

  Regularly inspect the power supply cables and plugs etc. for wear or damage and check all connections to ensure that none 

are loose. 

  Important: Ensure that the voltage marked on the appliance matches the power supply to be used and that a correctly rated 

fuse is fitted. 

  DO  NOT  use  worn  or  damaged  cables,  plugs  or  connectors.  Immediately  have  any  faulty  item  repaired  or  replaced  by  a 

qualified electrician. 

  The unit should be protected by a suitably rated isolator and fuse or MCB.  

  This air curtain is IP20 rated and is suitable for indoor or under cover use only. 

  Do not attach this air curtain to an extension cord it must be hard wired in position. 

1.2 GENERAL SAFETY INSTRUCTIONS 

 

Remove all packaging and store it away from children, check the package and air curtain for visible damage or tampering. 

 

Familiarise yourself with the applications and limitations of the air curtain. 

 

Ensure the air curtain is in good order and condition both physically and electrically before use. If in any doubt, do not use 
the unit and contact your supplier. 

 

Only  use  recommended  attachments  and  parts.  To  use  unauthorised  parts  may  be  dangerous  and  will  invalidate  your 
warranty. 

 

Keep tools and other items away from the air curtain when it is in use. 

 

Keep children and unauthorised persons away from the air curtain, as it gets 

hot. 

 

Disconnect from mains and allow to cool before attempting any cleaning or maintenance. 

X

  DO NOT

 use in areas where hazardous gasses or dusts may be present. 

X

  DO NOT

 locate the air curtain directly below the power outlet. 

X

  DO NOT

 disassemble the air curtain for any reason. This air curtain must be checked by qualified personnel only. 

X

  DO NOT

 use this air curtain to perform a task for which it has not been designed. 

 

WARNING!

 This air curtain is not equipped with a built in device to control the room temperature. Do not use this air curtain 

in  a  small  room  if  it  is  occupied  by  people  not  capable  of  leaving  the  room  on  their  own,  unless  constant  supervision  is 
provided.  

 

WARNING! 

Ensure  you  observe  the  safety  distances  and  mounting  heights  and  there  is  no  possibility  of  inflammable 

materials coming into contact. 

 

 

 

 

  PLEASE READ  THESE  INSTRUCTIONS,  NOTE  THE  SAFE  OPERATIONAL  REQUIREMENTS,  WARNINGS, 

AND  CAUTIONS.  USE  THIS PRODUCT CORRECTLY,  AND WITH  CARE  FOR  THE  PURPOSE  FOR WHICH  IT  IS  INTENDED. 
FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. 

 

INSTRUCTIONS FOR:- 

COMMERCIAL AIR CURTAIN 

Model:- CAT-90

 

REGISTER

: PLEASE REGISTER THIS PRODUCT ONLINE TO ACTIVATE YOUR GUARANTEE AT 

 www.

bnthermic

.co.uk 

Summary of Contents for CAT-90

Page 1: ...an The unit should be protected by a suitably rated isolator and fuse or MCB This air curtain is IP20 rated and is suitable for indoor or under cover use only Do not attach this air curtain to an exte...

Page 2: ...2 x M5 Lock washers 4 x M4 Nuts and 4 x M4 Washers 4 2 WALL MOUNTING ABOVE A DOORWAY Attach the two Small wall mounting brackets to the air curtain using the Plastic Domes and M2 9 Screws Make sure bo...

Page 3: ...n switch back to the fuse board use 10mm cable Drawings show connections inside the black terminal box on the outside of the air curtain Do NOT use power tools to undo or do up terminal screws Please...

Page 4: ...the power supply box Use minimum 1 5mm 5 Core Mains Cable see note above Connect Brown wire Terminal 1 or L Connect Black wire Terminal 2 Connect Grey wire Terminal 3 Connect Blue wire Terminal 5 or N...

Page 5: ...low wire Terminal E or of air curtain and earth connection on Thermostat PLEASE CHECK ALL CONNECTIONS BEFORE TURNING ON AS INCORRECT WIRING IS NOT COVERED BY THE GUARANTEE 6 2 Adding a Programmable Ti...

Page 6: ...the air curtain to the CS 7 Controller see note above Remove any links that may be present in air curtain Control Box between terminals 1 2 3 4 or 5 Air curtain Control Box to CS 7 Controller Cable C...

Page 7: ...s for reference only Move the Dark Brown link cable from the centre switch terminal 1 to the centre switch terminal 3 shown above by dark brown wire Connect Brown wire Terminal 1 or L of air curtain a...

Page 8: ...gn materials around the airways If the air curtain fails to operate or the safety cut out operates again turn off the air curtain and contact a qualified electrician The Air curtain is protected by a...