background image

3.5   

TerraE is not liable for any force majeure (ex. Lightening, storm, flood, fire, earthquake, etc)

3.6   

In order to standardize the use of sample batteries, the rights, obligations and responsibilities of every customer and 

TerraE are clarified. Before using the battery, please read carefully and thoroughly understand the contents of the specifica-
tion. In order to ensure the safety of the battery, please contact TerraE to discuss design of the application. Also, if there are 
special usage conditions (for example: a large current load, a quick charge method, or a special usage pattern), please consult 
TerraE before finalizing the product specification. 

If you choose to use this battery, your use will be regarded as an endorsement of all the contents of this statement. 

The amendment, renewal and final interpretation of this statement are belong to TerraE.

12

INR 18650 35 E

Handling Instructions

TerraE Confidential Proprietary and not be reproduced without written permission from BMZ Germany GmbH, Zeche Gustav 1, 63791 Karlstein

3. EXCLUSION LIABILITY

3.1   

TerraE is not liable for any loss caused by breach of notice in the specification

3.2   

TerraE is not responsible for any problems caused by design defects in battery packs, electric cars and chargers

3.3   

TerraE does not accept abnormal batteries caused by improper assembly

3.4   

TerraE is not liable for any loss caused by incorrect or incongruent with the SPEC charge and discharge method and 

inappropriate environment

2.3   PRECAUTIONS 

2.3.1 

Don’t use or place batteries in high temperature environments, such as in direct sunlight. The battery may catch 

fire, smoke, explode or cause heat. At the same time, may cause battery performance and life degradation.

2.3.2 

Battery pack has a protective line. Do not use batteries in places where static electricity (over 100V) is generated, 

which may damage the protection circuit. If the protective line of the battery is damaged, the battery may catch fire, 
smoke, explode or cause heat. Do not use Lithium ion cell with the primary batteries or secondary batteries whose ca-
pacity or kinds or maker is different. If do that, the cell will be discharged or charged excessively in use. And it may cause 
the generating heat, smoke, rupture or flame because of the abnormal chemical reaction in cells.

2.3.3 

Specified the charging temperature range. Do not charge the battery outside the specified temperature range. 

Failure to do so may result in heat, leakage, or serious damage. In addition, battery performance and life degradation 
may occur.

2.3.4 

Please read the manual before use. Please keep this manual for future reference. 

2.3.5 

Please read the charging method of the charger manual. 

2.3.6 

In the first use, if the battery has an abnormal smell, heat or rust, please contact the supplier. 

2.3.7 

Keep away from flammable materials during charging and discharging. May cause fire, smoke, explode or cause 

heat. 

2.3.8 

If the electrolyte leaks from the battery, gets on the clothes or on the skin, rinse it immediately with water. Other-

wise it may irritate the skin. 

2.3.9 

If wires or metal objects come out of the battery, completely seal and insulate them. Otherwise, the battery may 

cause a short circuit, fire, smoke, explosion, or cause heat. 

2.3.10 

After use, please carry out battery recycling according to local laws and regulations. 

Summary of Contents for TerraE INR 18650 35 E

Page 1: ...www bmz group com CELL SPECIFICATION INR 18650 35 E E MOBILITY DRIVE SYSTEMS POWER AND GARDENTOOLS INDUSTRIAL MEDICAL ENERGY STORAGE SYSTEMS ...

Page 2: ...ecification at 25 C TerraE Confidential Proprietary and not be reproduced without written permission from BMZ Germany GmbH Zeche Gustav 1 63791 Karlstein 3 60V CC CV Std 0 2C 4 2V cut off at 1 50C 8 0hrs 25 2 0 2 C 0 10 0 2C 10 20 0 3C 20 45 0 5C CC with 0 2C cut off at 2 5V 35mΩ AC 1kHz 80 SOH after 800 cycles at 25 C with 0 5C Cha 1C DCha 3 3 NOMINAL VOLTAGE 3 4 STANDARD CHARGING 3 5 CHARGING CU...

Page 3: ...erable capacity 90 3 13 STORAGE CHARACTERISTICS 3 14 TEMPERATURE Recoverable capacity 80 3 15 STORAGE TEMPERATURE Discharge CC 0 2C 2 5V cut off at each temperature 0 2C 25 100 SOC residual and recoverable capacity will be tested after 28 days at 25 2 25 Reletive humidity 45 75 40 50 SOC residual and recoverable capacity will be tested after 12 months charge and discharge 5 times Recommend storage...

Page 4: ...f 0 1mΩ 1mV 6 2 Unless otherwise specified all tests shall be performed at 25 C 2 C and relatively humidity 15 95 and atmosphere pressure 86 106KPa C Rate C The rate milliamperes at which a fully charged cell is discharged to its end voltage in one 1 hour 6 3 DEFINITION 7 CHARACTERISTICS 7 1 CHARGE METHOD 7 1 1 Charging shall consist of charging at a 0 2C constant current rate until the cell volta...

Page 5: ...the testing cells at 25 C 2 C for 28 days Then discharge as per 7 2 2 Then the same cell is fully charged as per 7 1 1 again and discharged a second time and measured as per 7 2 2 The recovery discharge capacity 2nd discharge capacity 90 of initial capacity 7 6 2 After charge as per 7 1 1 store the testing cells at 55 C 3 C for 7 days Then discharge as per 7 2 2 Then the same cell is fully charged...

Page 6: ... tapering the charge current Monitoring ch ange of cell temperature during testing The charge durati on is 7 hours Stop the test when cell temperature decays to room temperature Criteria No Fire No Explosion Cell fully charged per 7 1 1 is to be placed in the hot oven Store the testing cells connecting with thermocouple in constant temperature box heating the cells and box speed of ascending tempe...

Page 7: ...etch map Drawing 7 Attached 1 Cell Size Drawing INR 18650 35 E Cylindrical Lithium Ion Cell TerraE Confidential Proprietary and not be reproduced without written permission from BMZ Germany GmbH Zeche Gustav 1 63791 Karlstein ...

Page 8: ...circuit avoid produce turbulence 1 1 3 Charger should start charging at temperature range 0 C 45 C see spec 3 4 3 7 temperature tolerance 3 C When the cell temperature exceeds this range it should be placed in the battery temperature to teach the above range before recharging 1 1 4 For cycle life use the normal charging or trickle charging method and minimize the fast charge 8 INR 18650 35 E Handl...

Page 9: ...ot be connected to unauthorized equipment and equipment Both ends of the battery pack should be designed to avoid short circuits or positive and negative The battery pack design should have anti static function and can prevent the dust The battery should be designed so that even if the battery leakage occurs the electrolyte can not reach the protection circuit board Battery design should ensure th...

Page 10: ...ries need to be used before the detection of voltage resistance and in accordance with its use for the combination It is recommended at least to ensure that the use of batteries within 30mV voltage within the internal resistance within 6mΩ 1 5 2 Battery pack before shipment Check the voltage internal resistance protection line function thermistor thermal fuse 1 5 3 Transfer the batteries to the as...

Page 11: ...ery may catch fire smoke explode or cause heat 2 2 4 Don t use an abnormal battery If there are obvious abnormalities such as odor fever deformity or discoloration stop using the battery Such batteries may be defective and if used may cause fire smoke heat or explosion 2 1 3 Don t use non specified charging equipment and violate charging requirements Non specified conditions charge will cause the ...

Page 12: ...ents such as in direct sunlight The battery may catch fire smoke explode or cause heat At the same time may cause battery performance and life degradation 2 3 2 Battery pack has a protective line Do not use batteries in places where static electricity over 100V is generated which may damage the protection circuit If the protective line of the battery is damaged the battery may catch fire smoke exp...

Page 13: ...973 E Tokio Kobayashi bmz group com BMZ Company Ltd Julong Technology Building B Cuibao Road Longgang District Shenzhen Guangdong Province P R China 518116 P 86 755 8977 5800 E contact cn bmz group com BMZ France S A R L 45 Boulevard Vincent Auriol 75013 Paris France P 33 9 87 37 42 62 E nicolas noel bmz group com BMZ Poland Sp z o o Alberta Einsteina 9 44 109 Gliwice Poland P 48 327842 450 E BMZP...

Reviews: