05/2012
01 29 2 320 769
© BMW AG, Munich
(T/Z/Z)
8
Connect branches
A5–A6
as follows to plug
X11003
(SW 6-pin) on the front fuse holder:
- Branch
A5
, GE/SW cable, to PIN 5
- Branch
A6
, GE/RT cable to PIN 2
Insert blade terminal fuses
E
into slots F22 and F25 of the
front fuse holder (1).
Route branches
A1–A4
and
A7–A15
as follows along
the standard wiring harness:
- Branches
A1–A4
through the rubber grommet (1) into
the engine compartment and onward into the right
wheel arch
- Branches
A7–A15
into the right footwell
- Branches
A12–A15
through the rubber grommet (2)
into the engine compartment and onward into the left
wheel arch
In cars built up to 10/10, the footwell module (1)
must be renewed.
Connect branches
A7–A10
as follows on footwell
module (1):
- Connect branch
A7
, WS/BL cable, to PIN 3 of
plug
X14260
- Connect branch
A8
, WS/GN cable, to PIN 37 of
plug
X14261
- Connect branches
A9–A10
, GR/BR cable, with minia-
ture connector
D
to GR/BR cable from PIN 49 of
plug
X14261
X11003
A6
A5
1
071 0241 Z
F22
F25
E
1
071 0242 Z
A1-A4
A12-A15
A7-A11
1
2
071 0245 Z
X14261
X14260
A9-A10
A7-A8
1
D
071 0243 Z
5.
Installing and connecting the retrofit wiring harness