Battery Connection Procedure
The caravan battery should be connected as per the following steps.
1.
Remove mains power to the Genius-II
Turn off the power switch on the Genius-II
2.
Disconnect all loads
Turn off all 12V equipment connected to the Genius-II
3.
Connect the positive battery terminal
4.
Connect the negative battery terminal
If the battery negative is connected to chassis, ensure a connection exists
from chassis to the “Bat—VE” terminal of the Genius-II.
WARNING
Sparks have the potential to cause an explosion should combustible
gases be present. The following procedures are designed to minimise the
risk of spark generation while connecting or disconnecting the battery.
BATTERY CONNECTION/DISCONNECTION PROCEDURE
Battery Disconnection Procedure
The caravan battery should be disconnected as per the following steps.
1.
Disconnect all loads
Turn off all 12V equipment connected to the Genius-II or
disconnect the loads using the remove load-disconnect switch
2.
Remove mains power to the Genius-II
Turn off the power switch on the Genius-II
3.
Disonnect the negative battery
4.
Disconnect the positive battery terminal