contact
|
MFP62
USER MANUAL
09
RS-232 Control Port
Baud Rate:
57600 bps
Data Bit:
8-bit
Parity:
None
Stop Bit:
1-bit
Flow Control:
None
The MFP62 can be controlled via a 3-pin Phoenix to serial RS-232 cable (supplied). All RS-232 commands must be terminated with
a carriage return <CR> or \r. The communication settings and commands are as follows:
RS-232 COMMAND
DESCRIPTION
?
Print Help Information
HELP
Print Help Information
STATUS
Print System Status And Port Status
P ON/OFF
Set System Power On or Off
KEY ON/OFF
Set System Key Control On Or Off
IR ON/OFF
Set System IR Control On Or Off
LCD ON/OFF
Set LCD Always On Or Auto Turn Off In Power On State
RESET
Reset System To Default Setting
(Type “Yes” To Confirm, “No” To Discard)
RESET ALL
Reset System And Network To Default Setting
(Type “Yes” To Confirm, “No” To Discard)
OUT OSD ON/OFF
Set Scaler OSD Show On or Off
OUT RES rr
Set Scaler Output Resolution
rr=00: 1024x768@60Hz
rr=01: 1280x800@60Hz
rr=02: 1360x768@60Hz
rr=03: 1440x900@60Hz
rr=04: 1680x1050@60Hz
rr=05: 1920x1200@60Hz
rr=06: 720p@50Hz
rr=07: 720p@60Hz
rr=08: 1080p@50Hz
rr=09: 1080p@60Hz
rr=10: 4K2K@25Hz
rr=11: 4K2K@30Hz
rr=12: 4K2K@50Hz
rr=13: 4K2K@60Hz
rr=14: DCI 4K2K@25Hz
rr=15: DCI 4K2K@30Hz
rr=16: DCI 4K2K@50Hz
rr=17: DCI 4K2K@60Hz
rr=18: Auto
OUT FREQ mm
Set Output Frequency Mode
mm=AUTO: Set Output Freq To Auto Change To Input Freq
mm=FORCE: Set Output Freq By CMD OUT RES rr Select
OUT xx ON/OFF
Set Output xx On Or Off
xx=00: Select All OUTPUT Ports
xx=[01...02]: Select One OUTPUT Port
OUT xx FR yy
Select Input Port yy
yy=[01...03:HDMI, 04:DP, 05:USB-C, 06:VGA]
NET DHCP ON/OFF
Set Auto IP(DHCP) ON Or OFF
NET IP xxx.xxx.xxx.xxx
Set IP Address
NET GW xxx.xxx.xxx.xxx
Set Gateway Address
NET SM xxx.xxx.xxx.xxx
Set Subnet Mask Address
NET RB
Set Network Reboot and Apply New Config!!!
NET TN xxxx
Set Telnet Port