BLUM RC66 Installation Instructions Manual Download Page 10

System overview

RC66 | 08-2021

10

Blum-Novotest GmbH

3.4

Technical data

3.4.1 Dimensions

Fig. 3-3 Dimensions [mm] RC66.

Protection class

IP68

Operating voltage U

B

 (stabilised DC voltage)

12…13V / 100mA via interface

Signal transmission

Radio

Frequency band

2.4…2.5GHz

Max. transmission power

0dBm

Transmission range

15m – see

3.5 Area of work

Min. bending radius cable

60mm (application: flexible)

Max. cable length

50m

Storage temperature

-20 ... +70 °C 

Operating temperature

+5 ... +50 °C

Ø 44

9,5

55

Ø 20…38

3,2

Ø 6

Ø 3,3 (M4)

45

37

Ø 6,3

Ø 40

1 2

3

4

5

(1) Machine wall opening
(2) O-ring 40× 2(NBR 70)

(3) 4× holding screws M3×10 (ISO 4726)
(4) 4× holding screws M4×10 (ISO 4726)

Summary of Contents for RC66

Page 1: ...1 Radio receiver Installation instructions Type RC66 Radio Transmission For Touch Probes For Tool Setting Probes For Bore Gauges For Special Measuring Systems ...

Page 2: ...H including reproduction copying publication and translation Translation of the original German document The language version of the manufacturer DE is relevant for the technical content Subject to technical change without notice All brands stated in this document are the property of the respective brand owner Article number of this documentation 257414 ...

Page 3: ...3 1 Measuring system 7 3 2 Description 8 3 3 Display elements 8 3 4 Technical data 10 3 4 1 Dimensions 10 3 5 Area of work 11 4 Mounting 12 4 1 Selecting the installation position 12 4 2 Mounting variants 12 4 2 1 Horizontally facing cable 12 4 2 2 Cable outgoing downward 12 4 2 3 Front kit 13 4 3 Electrical connection 13 4 4 Device marking 13 5 Maintenance 14 6 Order numbers 15 7 Shipping instruc...

Page 4: ...check mark indicates the required preconditions The white triangle prompts you to carry out an action The arrow indicates the consequences of your action 1 The number in brackets refers to a respective item in an illustration Here you will find additional instructions and tips x This character in a file name or similar acts as a place holder for the version level numbering etc LED is lit Green Red...

Page 5: ...ion by trained technical personnel 2 2 Further applicable documents Measuring system data sheets for any measuring devices receivers interfaces extension modules and accessory products involved Measuring system operating instructions as appropriate measuring devices involved Measuring system installation instructions as appropriate receivers interfaces extension modules involved Wiring diagrams Wi...

Page 6: ...tection Always lay measuring system cables and control lines for motors in separate ducts NOTICE Damage to and malfunction of the measuring system resulting from faulty grounding due to coated DIN rail etc Always ensure reliable grounding of the measuring system NOTICE Damage to the measuring components due to improper assembly Use BLUM original spare parts only Use the included special BLUM tools...

Page 7: ...System overview RC66 08 2021 Blum Novotest GmbH 7 3 System overview 3 1 Measuring system Fig 3 1 Overview of compatible components examples NC EM34 EM32 EM31 EM30 1 x NC IF59 A2 I O SSI IF59 30 A2 ...

Page 8: ...1 TC Z ZX Probe 2 Probe 6 DIGILOG RG Probe 1 Probe 6 BG Probe 1 Probe 16 KOMflex Probe 1 Probe 16 Pairing YE Status LED TC Z ZX Measuring device home position BG Connection established KOMflex Connection established Pairing successful TC Z ZX Measuring device deflected BG Collision MG Collision KOMflex Connection failed Pairing unsuccessful TC Z ZX Connection interrupted BG Connection being establ...

Page 9: ...est GmbH 9 Battery LED Battery is good Pairing successful Battery low Pairing unsuccessful No battery data Pairing not yet performed YE Receive LED Valid data Invalid faulty data No data Transmit LED Send data Activate deactivate No data YE ...

Page 10: ...nsmission Radio Frequency band 2 4 2 5GHz Max transmission power 0dBm Transmission range 15m see 3 5 Area of work Min bending radius cable 60mm application flexible Max cable length 50m Storage temperature 20 70 C Operating temperature 5 50 C Ø 44 9 5 55 Ø 20 38 3 2 Ø 6 Ø 3 3 M4 45 37 Ø 6 3 Ø 40 1 2 3 4 5 1 Machine wall opening 2 O ring 40 2 NBR 70 3 4 holding screws M3 10 ISO 4726 4 4 holding scr...

Page 11: ...021 Blum Novotest GmbH 11 3 5 Area of work Fig 3 4 Wireless communication range 0 0 15 30 45 60 75 15 30 45 60 75 90 16 14 12 6 15 30 45 60 75 15 30 45 60 75 90 8 2 4 10 0 15 30 45 60 75 90 16 14 12 10 15 30 45 60 75 90 8 2 4 6 ...

Page 12: ... drilling template included 4 2 Mounting variants 4 2 1 Horizontally facing cable Fig 4 1 RC66 Installation with horizontally facing cable 4 2 2 Cable outgoing downward Fig 4 2 RC66 Installation with cable facing downward 1 2 3 1 2 4 5 2 5mm M3 1 3N m max 3mm M4 3 0N m max 1 Seal insert 2 O ring 40 2 NBR 70 3 Machine wall 4 4 holding screws M3 10 ISO 4762 5 4 holding screws M4 10 ISO 4762 1 2 4 3 ...

Page 13: ...ing devices colour marking of the devices can be helpful to prevent mix ups Always use transparent protective adhesive labels as well 3 1 2 4 3mm M4 3 0N m max 1 Cover ring 2 4 holding screws M4 25 ISO 7380 3 Machine wall 4 O ring 40 1 5 NBR 70 Blum Novotest Item No 176973 RC66 Battery o k Battery low No communication www blum novotest com Send command Initial position Probe deflected No communica...

Page 14: ...hols benzines etc Only use coolant with a pH value in the range of 4 5 9 5 Never use cleaning agents containing acetone Always exercise caution when using cleaning agents containing solvents alcohols benzines etc or a high acidic alkaline pH value avoid long periods of exposure Never use abrasive cleaning agents cleanser scouring powder etc Clean the receiver regularly Remove chips regularly ...

Page 15: ...ers RC66 08 2021 Blum Novotest GmbH 15 6 Order numbers Use original parts and accessories by Blum Novotest only Front Kit RC66 143002 Heavy Duty Kit Protection spring 1m incl threaded connection For cable 142680 ...

Page 16: ...mination Ensure that the measuring device is not deflected inside the packaging Please complete this repair order answering all questions in detail and attach it to the system It will be more cost ef fective for both parties if we have all the information and will ensure a prompt repair service Blum Novotest GmbH Haldenstrasse 6 88287 Gruenkraut Germany tel 49 751 6008 0 fax 49 751 6008 156 Compan...

Page 17: ... of Conformity The required technical documentation has been prepared We undertake to send specific information concerning the components to competent offices in individual member states in writing if ordered to do so with good reason The indus trial property rights of Blum Novotest GmbH will remain unaffected Component name Radio receiver RC66 Applied regulations and standards EC regulations 2014...

Page 18: ... subject to the following two conditions 1 This device may not cause interference 2 This device must accept any interference including interference that may cause un desired operation of the device Cet appareil contient des émetteurs récepteurs exemptés de licence conformes aux RSS RSS d Innovation Sciences et Développement économique Canada Le fonctionne ment est soumis aux deux conditions suivan...

Page 19: ...19 10 Service Head office Blum Novotest GmbH Kaufstraße 14 88287 Gruenkraut Germany Phone 49 751 6008 0 Sales sales blum novotest com Phone 49 751 6008 200 Service service blum novotest com Phone 49 751 6008 202 Homepage www blum novotest com ...

Page 20: ......

Reviews: