background image

6 (7)

FWTU-2835T-112-24

Attentions before installation

- Check whether the power line is screwed into the terminal firmly, and it is better not to pull it out by hand.
- Before installation, check that the product parameters are consistent with the requirements (Seeing product specifications or product labels) 
- Load voltage, current, power and power supply should be matched with the product.
- Follow the instructions of wiring diagram (first connect the load and then the power supply) to avoid short circuit.
- Make sure the correct connection of positive and negative poles between products and power supply. Otherwise, the light will not be on.
- The wiring terminal must be provided with effective waterproof and anti-corrosion treatment.

Common Faults and Troubleshoot

Quick Guide

Problems

All LEDs can not light on.

LEDs can not light on partly.

Brightness of LED is 
inconsistent tor insufficient.

LED flicker.

Automatic power protection from the open or short 
circuit in output of the power supply.

Fix the short circuit problem.

Correctly connection.

Replace with more powerful power.

Make sure the working voltage of the product within ±5% of 
standard voltage, or keep balance by circuit power consumption.

Reduce the quantities of the product in series connection 
to meet requirement.

Wrong connection of power supply.

Some switching mode power supplies are not powered.

Power supply line error.

Mistaken wire connection of some of products

Power overloaded.

Connection point fault.

Remove bad connection point.

Replace a new power supply.

Please follow the instructions

Power supply circuit excessive consumption.

Excessive quantities in series connection of the product

Switching power supply failure.

Wrong Installation or use of products

Reasons

No electric supply.

Solutions

Warning

- Do not disassemble or retrofit the light. Do not touch the surface of the light with a sharp object.
- Do not do live-line working during installation,especially for high voltage product.
- Do not use any organic chemical solvents.
- Use neutral glass adhesive to fix this product and it needs to be dried 4 hours in the open environment after operation.
- Treat the ends and the circuit connection points that are not connected to the main line with insulation,waterproof, and anti-corrosion in the installation.
- Use 18AWG (0.75mm² cross-sectional area) or thicker core wire to avoid adverse consequences caused by overheating, if the power cable need to lengthen.
- Make sure the input voltage meets the requirements and lines are connected correctly before lighting on.
- This product is for signage, and do not use as general lighting.
- Use 1 mm² cross-sectional area or thicker core wire to avoid adverse consequences caused by overheating, if the power cable need to lengthen.
- Make sure the input voltage meets the requirements and lines are connected correctly before lighting on.
- Series connection within the max run.
- The length of the power cable between the power supply and the led strip should not exceed 2 meters. Otherwise, large circuit loss will lead to inconsistent brightness.
- Installation, maintenance and repair should be operated by a qualified technician.
- For non replaceable light sources: the light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.
- Do not connect the rope light to the supply while it is in the packing or wound onto a reel.
- Do not use the rope light when covered or recessed into a surface.
- The external flexible cable or cord of this luminaire cannot be replaced; if the cord is damaged, the luminaire shall be destroyed.
- For operation only with safety isolating transformer.
- This product needs to be cleaned regularly during use, and cannot be cleaned with oily, strong alkaline, strong acid and other chemical cleaners.

isolated power supply

Summary of Contents for FWTU-2835T-112-24

Page 1: ...cal Parameters Model No 2835 DC 24V 3Years IP68 Installation LED Driver Version C1 2 Other Parameters 20 55 C 20 70 C LED QTY Working Temperature Storage Temperature No Brightness Difference single feed Model No Standard Packing Length NOTE The above data was measured under standard conditions and actual data may be different We would update data without further notice The luminous flux was tested...

Page 2: ... ambient temperature Exceeding the maximum ambient temperature may damage LED chips reduce the total lamp life luminous intensity output and or adversely impact color consistency Operating temperature was measured under the minimum and maximum ambient temperature environment Cutting segments are marked on the profiles below If the product power is greater than 15W auxiliary heat dissipation applia...

Page 3: ...r environment test Blueview Blueview Third party Third party Project Category Test conditions Please refer to the report for details Immerse the sample into an ordinary pool immersed depth 100cm Please refer to the report for details Immerse the sample in artificial seawater solution pH 7 5 8 0 immersed depth 10cm Outcome Pass Testing agency Artificial seawater test Seawater immersion test IP test...

Page 4: ...lustrated packaging method There will be differences in the quantity and weight with other packaging methods Installation Cutter Electric drill LED power supply Screw Clips Packaging Information Label the reel Seal the carton box Use packing belt to pack Add edge protectors if necessary Put reel accessory bag and desiccant together into static shielding bag Seal and label the static shielding bag ...

Page 5: ...ing pool clean the mounting surface and mark the mounting position Fix the clips at the mounting position with screws Make sure the luminous surface is flat then light on to test Mounting Position Mounting position 1 Mounting position 2 Mounting position 3 Mounting position 4 ...

Page 6: ...the light Do not touch the surface of the light with a sharp object Do not do live line working during installation especially for high voltage product Do not use any organic chemical solvents Use neutral glass adhesive to fix this product and it needs to be dried 4 hours in the open environment after operation Treat the ends and the circuit connection points that are not connected to the main lin...

Page 7: ...trations and drawings in this manual are for reference This product is subject to change without notice Statements LED lighting products belongs to electronic products please do recycling treatment according to the relevant WEEE directives Recycling BLUEVIEW ELEC OPTIC TECH CO LTD Tel 86 28 8148 0011 Fax 86 28 8148 1258 Web www blueviewled com Email sales blueviewled com Add No 1000 Section 2 Kong...

Reviews: