Bluetti Split Phase Fusion Box PRO P030A User Manual Download Page 4

BRIEF INTRODUCTION

Split Phase is used for connecting two EP500Pro units (exclusive for the 100-120V version)
by bonding them effectively into one larger power system to double the output power,
voltage, and capacity to 6000W Max @ 220-240V, 10240Wh.

- 01 -

(EP500Pro Split Phase Power System)

Summary of Contents for Split Phase Fusion Box PRO P030A

Page 1: ...P030A Split Phase Fusion Box PRO Please read this manual before use and follow its guidance Keep this manual for future reference ...

Page 2: ...User Manual Please read this manual before use and follow its guidance Keep this manual for future reference ...

Page 3: ...Contents BRIEF INTRODUCTION 01 SAFETY INSTRUCTION 02 IN THE BOX 03 FEATURES OF P030A 04 LET S GET STARTED 05 CONNECTION 1 Standard Mode 05 CONNECTION 2 Power Mode 06 WRONG CONNECTION 07 DECLARATION 08 ...

Page 4: ...for connecting two EP500Pro units exclusive for the 100 120V version by bonding them effectively into one larger power system to double the output power voltage and capacity to 6000W Max 220 240V 10240Wh 01 EP500Pro Split Phase Power System ...

Page 5: ...rior component of the equipment by anyone other than authorized personnel DO NOT operate P030A in wet conditions If the equipment becomes wet please let the unit dry completely before using Please ensure proper ventilation while in use and do not obstruct fan openings Inadequate ventilation may cause permanent damage to P030A Warning DO NOT insert foreign objects into any ports of the P030A P030A ...

Page 6: ...IN THE BOX 03 Split Phase Fusion Box Pro x1 pcs Certificate of QC Pass x1 pcs User Manual x1 pcs Communication Cable x1 pcs ...

Page 7: ...s RV 30 The TT 30R receptacle is commonly available in nearly all RV parks in the United States and Canada c Standard AC receptacle wildly used in 100 120V areas generates the almost same AC power as a household wall outlet d When Split Phase System installation finished successfully both of the two LED lights stay ALWAYS ON If the LED light is not active please check the connection FEATURES OF P0...

Page 8: ...he default machine type as operating one single EP500Pro or AC300 b Select Master or Slave on touchscreen of the operating EP500Pro AC300 Tap Settings Next Machine Type c Tap Master on touchscreen will set the operating EP500Pro AC300 as the one to control both two EP500Pro AC300 d Then select Slave on another unit to set the as the one controlled by another one EP500Pro AC300 Master e Tap clear t...

Page 9: ... Input Cable Optional Purchase is designed to match Split Phase System One end of the cable is connected to NEMA L14 30 socket and the other end is connected to AC input interface of both two units through aviation plug It must be ensured that the phase of the two machines is correct The current capacity of AC input plug shall be 30A 06 CONNECTION 2 Power Mode L1 N PE PE G PE L2 W N L1 X L1 N Y L2...

Page 10: ...ing is ON please use AC Input Cable Optional Purchase to charge both of your power stations in Split Phase System WRONG CONNECTION 07 Wrong Connection will damage the battery inside the power station and your warranty will be invalid PE G PE W N L1 X L1 N PE G PE W N L1 X L1 N ...

Page 11: ... for utilizing non standard adapters and accessories Our company is not liable for any damages caused by any operations of the product outside of the usage methods detailed in this manual This unit is not suitable for use on the relevant equipment or machines involving Personal safety such as atomic energy devices aerospace devices emergency medical devices etc or any equipment or machines that re...

Page 12: ... 10 P N 17 0303 0387 00A0 ...