Do Not Duplicate, Alter, or Copy without the Express Written Consent
of BlueSky Mast, Inc. Copyright 2013 Allendale LLC All Rights Reserved
AL3 Lift Series - Deployment Quick Reference Sheet
Read Manual Before Use
Refer to detailed instructions in the
AL3 Lift Series Manual at all times
Tighten the nut on the cam lock
a quarter turn until slipping no
longer occurs.
Slide the guy handle towards
the mast approx. 7 feet and
drop on the ground.
Continue this process until all 4
primary guy ropes have been
deployed 90 degrees apart.
Make sure the cam lock is
locked and lower the lift base
plate to the ground.
Raise the center mast pole until
it nest together into the bottom
of the mounting pole.
Release the cam lock and raise
until 1 inch is showing below the
tripod. LOCK THE CAM LOCK
WARNING: If at any point the
mast begins to slip while the
cam lock is locked - STOP
Use the 7/16 wrench provided
with the system to make adjust-
ments.
Insert a center mast pole onto
the tapered cone on the lift base
plate.
Insert all 3 struts into the
receivers on the strut base plate
and secure the hitch pins.
Make sure the strut base plate
is centered under the tripod and
tighten all turn knobs.
Locate the
RED TIPPED strut
base plate stake
and hammer
it into the strut base plate.
Confirm the cable is taut and
the lift base plate is secure.
Release the cam lock on the
tripod and raise the mounting
pole by turning the winch.
Unwind the guy rope and take
one normal step per meter of
height. 15 Meters = 15 Steps
Unwind all the remaining guy
rope and drive 2 stakes through
the dual stake plates.
Leave 1 inch below the cam
lock and lock the cam lock.
Pin the
Red Primary Guy Ring
to the Mounting Pole below your
devices.
Attach the red clip from the
primary guy rope to the round
hole on the guy ring.
Continue this process until you
have reached 1/2 the total mast
height.
31
32
33
34
35
36
37
38
39
40
21
22
23
24
25
26
27
28
29
30
1”
1”