4

How to check the state of charge

Out from the box, the internal battery of MVQUICKAL has a state of
charge of about 50% or higher.

To verify the state of charge:

When the external battery is installed:
Press the “Check” button to verify the state. The LED will stay
on for about 3 sec showing the state (see table above). The
LEDs will flash when the internal battery is being charged.

When the external battery is not installed:
The LEDs are automatically alighted continuously displaying
the state of charge. However, if 60 minutes elapse without an
installation of a new battery, MVQUICKAL enters in a low
power mode and automatically shuts off. Press the “Check”
button to wake up the device and verify the state (see later).

The prediction of the state of charge based on cell voltage may
appear inaccurate especially when the device is requesting a high
current load. Under similar circumstances, the internal voltage drop
may be large enough to switch off the first LED [H] and apparently
displays a state of charge below 66%. In similar cases the LED
gauge is programmed with a pessimistic capacity prediction, and the
state of charge seems to reduce faster, especially for the first and
even the second LED [H M]. In any case the flashing 3

rd

 LED

represents a critical threshold after which the camera should be
switched off or alternatively, a fresh battery installed.

How to charge the internal battery

MVQUICKAL has an internal battery pack that can be charged in
two different ways:

By connecting the MVQUICKAL charger provided through the
Push-pull connector on the side.
The internal battery will be charged automatically. The charger
will charge at 3A in constant current mode with the charge time
being roughly 30 minutes.

Automatically upon installation of a new battery:
Whenever an empty battery is swapped with a fresh battery, the
newly installed battery will restore the lost energy of
MVQUICKAL by charging the its internal battery with a 120mA
current for a maximum time of 90 minutes. This will ensure that
a maximum of 180mAh will be replenished in the internal
battery.

Summary of Contents for MVQUICKAL

Page 1: ...www blueshape net Printed in Malta 2011 HOT SWAP SYSTEM FOR ALEXA USING V LOCK LITHIUM ION BATTERIES Model MVQUICKAL OPERATING INSTRUCTIONS Revision 1 0...

Page 2: ...tionally MVQUICKAL provides an alternative power source of about 21Wh to be used as a UPS in case of a sudden power failure or extended power demands during shooting MVQUICKAL graphic description 1 In...

Page 3: ...thout any power interruption As soon as this switchover takes place and MVQUICKAL operates through its internal power source the 3 LEDs become alighted depending on the state of charge to alarm the us...

Page 4: ...o switch off the first LED H and apparently displays a state of charge below 66 In similar cases the LED gauge is programmed with a pessimistic capacity prediction and the state of charge seems to red...

Page 5: ...ED button is not pressed during this period b To force a switch off remove the external battery and press and hold the LED button for about 5 seconds until the LEDs go off When MVQUICKAL is operating...

Page 6: ...2 F 86 F Dimensions 142 x 83 x 65mm Weight 750g Bottom spacer contact pin description 1 Positive ve Range 16 8V max to 12V min 2 Negative Ground ve 0V 3 Data communication Exercise caution handling th...

Page 7: ...mate the 3 golden contact pogo pins with the contact area on the camera 2 Screw in the 4 x M3x10 shorter screws provided 3 Figure shows lower Alu spacer part fixed to camera Note the 2 large terminal...

Page 8: ...8 4 Figure shows the main upper body brought into proximity of the lower body for connection 5 Screw in the main body using the 4 x M3x48 longer screws provided 6 MVQUICKAL is now ready to use...

Page 9: ...of product failure for which warranty applies we will repair or replace the product free of charge In these cases all expenses including transport charges will be borne by us In the case where the fai...

Page 10: ......

Page 11: ...11...

Page 12: ...NEW CELL TOP Srl VIA LIGURIA 4 6 42124 REGGIO EMILIA ITALY TEL 39 0522 518556 FAX 39 0522 277084 WEB www blueshape net EMAIL info blueshape net...

Reviews: