INSTALLATION INSTRUCTIONS

BHP15 SPLIT SYSTEM HEAT PUMP

(R410A REFRIGERANT)

 

(P) 506318-03B

*P506318-03B*

Manufactured By

Blue Summit LLC

8201 C National Turnpike

Louisville, KY 40214

This manual must be left with the homeowner for future reference.

This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in 

manuals, be alert to the potential for personal injury or death.

Installation or repairs made by unqualified persons can 

result in hazards to you and others. Installation MUST 

conform with local building codes and with the National 

Electrical Code NFPA 70/ANSI C1-1993 or current 

edition and Canadian Electrical Code Part 1 CSA C22.1.

 WARNING

Improper installation, adjustment, alteration, service 

or  maintenance  will  void  the  warranty.  The  qualified 

installer or agency must use factory-authorized kits 

or accessories when added to this products. Refer to 

the  individual  instructions  included  with  the  specific 

accessory kit.

 CAUTION

These instructions are intended as a general guide and 

do not supersede national, state or local codes in any 

way.

NOTE

These instructions and warranty are to be given to the 

owner or displayed near the indoor air handler unit.

NOTE TO INSTALLING DEALER

Before installing, modifying, or servicing system, main 

electrical disconnect switch must be in the OFF position. 

There may be more than 1 disconnect switch. Lock out 

and tag switch with a suitable warning label. Electrical 

shock can cause personal injury or death.

 WARNING

Table of Contents

Safety Precautions ......................................................2

Installation ...................................................................2

Electrical Connections .................................................5

Start-Up Procedure......................................................6

Operation .....................................................................7

Homeowner’s Information .........................................10

Summary of Contents for BHP15

Page 1: ...WARNING Improper installation adjustment alteration service or maintenance will void the warranty The qualified installer or agency must use factory authorized kits or accessories when added to this p...

Page 2: ...snow or ice from roof or eaves cannot fall directly on unit These units are designed for use in residential and light commercial type buildings Heat Pumps may only be installed with indoor combination...

Page 3: ...030 3 8 3 8 3 4 3 4 036 3 8 3 8 7 8 7 8 042 3 8 3 8 7 8 7 8 048 3 8 3 8 7 8 7 8 060 3 8 3 8 7 8 1 1 8 Field supplied 7 8 x 1 1 8 connector required on both ends of vapor tubing Table 1 Recommended Liq...

Page 4: ...een closed after final testing at the factory DO NOT disturb these valves until the lines have been leak checked and evacuated or the charge in the unit may be lost 1 Connect the vacuum pump to the ce...

Page 5: ...t should occur The ground may consist of electrical wire or metal conduit when installed in accordance with existing electrical codes Failure to follow this warning can result in an electric shock fir...

Page 6: ...re final adjustment is made to the refrigerant charge it is imperative that proper indoor airflow be established Airflow will be higher across a dry coil versus a wet coil Blower charts are calculated...

Page 7: ...tomatic switching from normal heating operation to defrost mode and back During compressor cycle the control accumulates compressor run times at 30 60 or 90 minute field adjustable intervals If the de...

Page 8: ...the following conditions during the defrost cycle and 90 seconds after the termination of defrost when the average ambient sensor temperature is below 15 F 9 C for 90 seconds following the start up of...

Page 9: ...Page 9 of 11 506318 03B Issue 1850 Figure 4 H P 15 SEER Wiring Diagram...

Page 10: ...Operation The wall mounted thermostat controls your air conditioner The thermostat is available in various configurations from different manufacturers The information below is typical for most thermos...

Page 11: ...n into coils by movement of the air Clogged condenser coils will lower the efficiency of your unit and could cause damage to the condenser Periodically debris should be brushed from the condenser coil...

Reviews: