background image

Blueprint

®

 Controllers put the power of automation to work in garden environments everywhere. For safety and optimal performance, 

please carefully read this document 

in full

 before installing and operating this Blueprint

®

 CO

2

 Generator.

rev:92014

Features

•  Two, four, eight or ten preinstalled liquid propane or natural gas burners

•  Electronic ignition provides reliable starts

•  Dual solenoid valves eliminate open pilot fl ame

•  Includes gas regulator, 12’ hose and hanging hardware

•  Built-in safety tip-over switch

•  Three-year warranty

Liquid propane hose 

with regulator

Natural gas hose 

with regulator

24-VDC power supply

Hardware

Specifi cations

Liquid Propane (LP)

Max. Area

Size (Cu Ft)

Max. CO

2

 

(Cu Ft/Hr)

BTU  Rating

Variable Output

Gas Pressure

Power 

Requirements

Dimensions

CGLP-2

2,000

5.3

2,263-4,526

1-2 burners

11” WC/2.8 kPa

400 mA @ 24-VDC

9” x 10” x 18”

CGLP-4

4,000

10.6

2,263-9,052

1-4 burners

15” x 8.5” x 18”

CGLP-4H

4,000

8.4

1,788-7,152

1-4 burners

15” x 8.5” x 18”

CGLP-8

8,000

21.2

2,263-18,104

1-8 burners

15” x 9.8” x 18”

CGLP-8H

8,000

16.7

1,788-14,304

1-8 burners

15” x 9.8” x 18”

CGLP-10

10,000

26.5

2,263-22,630

1-10 burners

15” x 9.8” x 18”

Natural Gas (NG)

Max. Area

Size (Cu Ft)

Max. CO

2

 

(Cu Ft/Hr)

BTU Rating

Variable Output

Gas Pressure

Power 

Requirements

Dimensions

CGNG-2

2,000

5.4

2,767-5,534 

1-2 burners

4.5” WC/1.15 kPa

400 mA @ 24-VDC

9” x 10” x 18”

CGNG-4

4,000

10.8

2,767-11,068

1-4 burners

15” x 8.5” x 18”

CGNG-4H

4,000

9.6

2,455-9,820

1-4 burners

15” x 8.5” x 18”

CGNG-8

8,000

21.6

2,767-22,136

1-8 burners

15” x 9.8” x 18”

CGNG-8H

8,000

19.2

2,455-19,640

1-8 burners

15” x 9.8” x 18”

CGNG-10

10,000

27.7

2,767-27,670

1-10 burners

15” x 9.8” x 18”

Summary of Contents for CGLP-2

Page 1: ...utput Gas Pressure Power Requirements Dimensions CGLP 2 2 000 5 3 2 263 4 526 1 2 burners 11 WC 2 8 kPa 400 mA 24 VDC 9 x 10 x 18 CGLP 4 4 000 10 6 2 263 9 052 1 4 burners 15 x 8 5 x 18 CGLP 4H 4 000 8 4 1 788 7 152 1 4 burners 15 x 8 5 x 18 CGLP 8 8 000 21 2 2 263 18 104 1 8 burners 15 x 9 8 x 18 CGLP 8H 8 000 16 7 1 788 14 304 1 8 burners 15 x 9 8 x 18 CGLP 10 10 000 26 5 2 263 22 630 1 10 burne...

Page 2: ... Indicators There are four LED indicators on the side of the Generator near the power switch The Main Power ON LED illuminates when the power supply is connected and the unit is turned on The Lock Out Error LED flashes to indicate the ignition control module has shut off the solenoid valves and the unit will not operate until it has been disconnected from and reconnected to power The Pilot Valve O...

Page 3: ... ensure all burners ignite correctly and consistently FAQ I smell gas around the generator is that normal No Turn off the gas supply immediately Do not turn on any electrical devices Ventilate the area and leave until the gas smell dissipates Turn the gas supply back on then determine where the leak is by spraying soapy water on the gas connections Retighten the connections where bubbles appear Wh...

Page 4: ...injury caused to other products machinery buildings or property loss of profits time or product or inconvenience This warranty is given in lieu of all other warranties express or implied including without limitation merchantability and fitness for a particular purpose Some states do not allow the exclusion or limitation of incidental and consequential damages or limitations on how long an implied ...

Reviews: