Safety

1.   Read carefully before usage.

2.   The Skim 300- 500-750 and 1250 are  is only suitable for indoor use.

3.   Ensure voltage shown on the label match to the mains supply voltage.

4.   Ensure that water cannot reach the socket.

5.   Never let the pump run dry, keep it submerged at all times.

6.   Disconnect skimmer from mains before any maintenance on your aquarium.

7.   If damaged the supply cord cannot be replaced, the whole pump needs to

 

be replaced.

8.   This appliance is not intended for use by persons (including children) with reduced

 

physical, sensory or mental capabilities, or lack of experience and knowledge,

 

unless they have been given supervision or instruction concerning use of the

 

appliance by a person responsible for their safety. Special care should be taken

 

with the use of electrical equipment by or near children.

GB

Instruction Manual

Installation Skim 300

1.  Unscrew the 4 nylon screws on the  

 

bottom plate (15) and disconnect the air  

 

venture (9).

2.  Lift the skimmer body off.

3.  place the bubblecatcher in front of the  

 

wateroutlet in the skimmerhousing (13).

4.  Put the skimmer body back in place and  

 

secure with the 4 nylon screws (15).

5.  Re-assemble the air venture (9).

6.  Connect the air venturi (9) to the air  

 

silencer (4) by using the supplied air  

 

hose (7).

7.  Place the skimmer inside your sump and  

 

open the water outlet fully by using the  

 

adjusting knob (12).

8.  Plug the pump in to the power outlet.

9.  Adjust the level of skimming by turning  

 

the knob (12) adjusting the  

 

water outlet (14).

10.  Be careful using the skimmer just after  

 

you have filled your tank with freshly  

 

mixed salt as this can cause extreme  

 

foaming and overflow.

Installation Skim 500, 750 and 1250

1.  Unscrew the 4 nylon screws on the  

 

bottom plate (15) and disconnect the  

 

air venture (9).

2.  Lift the skimmer body off.

3.  Adjust the first bubble plate so that the  

 

clear part is facing above the pump  

 

outlet (13).

4.  Re-assemble the second bubble plate and  

 

secure with the nylon screw (14).

5.  Put the skimmer body back in place and  

 

secure with the 4 nylon screws (12).

6.  Re-assemble the air venture (9).

7.  Connect the air venturi (9) to the air  

 

silencer (4) by using the supplied air hose.

8.  Place the skimmer inside your sump and  

 

open the water outlet fully (by rotating the  

 

arrows towards each other) by using the  

 

adjusting knob (10).

9.  Plug the pump in to the power outlet.

10.  Adjust the level of skimming by  

 

 

turning the knob (10)

11.  Be careful using the skimmer just after  

 

you have filled your tank with freshly  

 

mixed salt as this can cause extreme  

 

foaming and overflow.

Summary of Contents for Skim 1250

Page 1: ...1 GB Instruction Manual F Mode d Emploi NL Gebruiksaanwijzing D Gebrauchsanweisung Skim300 500 750 1250...

Page 2: ...raube Wasserstand 13 Bl schenf nger 14 Wasserauslass 15 Verbindungsschrauben Sockel und Geh use 1 Couvercle collecteur 2 Collecteur 3 Vis du silencieux 4 Silencieux principal 5 ntr e ozone 6 Robinet d...

Page 3: ...tigung der Luftplatten 15 Grundplatte 16 Gummikappe 17 Einstellbarer Lufteinlass 1 Couvercle collecteur 2 Collecteur 3 Vis pour d monter le silencieux 4 Silencieux principal 5 Entr e Ozone 6 Tuyau air...

Page 4: ...the air venture 9 6 Connect the air venturi 9 to the air silencer 4 by using the supplied air hose 7 7 Place the skimmer inside your sump and open the water outlet fully by using the adjusting knob 12...

Page 5: ...w unit but only in proportion 1 to 1 a differentiated refuse collection is environmentally friendly and it helps the recycling of the materials any other collection procedure is unlawful and will be s...

Page 6: ...ieder an 5 Setzen Sie die Venturid se 9 wieder ein 6 Verbinden Sie die Venturid se 9 mittels des Luftschlauchs 7 mit dem Schalld mpfer 4 7 Stellen Sie den Skimmer in Ihren Sumpf und ffnen Sie den Wass...

Page 7: ...er te bringen Oder wenn der die Besitzer in ein neues Ger t kaufen m chte kann er sie das alte Ger t beim Verk ufer hinterlassen Nur 1 zu 1 austauschbar Getrennte Sammlung ist umweltfreundlich und tr...

Page 8: ...f rieur et vissez la vis Nylon 13 4 Replacez le corps de l cumeur et vissez les 4 vis Nylon 15 5 Remontez le venturi 9 6 Connectez le 9 au silencieux 4 avec le tuyau air 7 7 Installez l cumeur dans la...

Page 9: ...sationetcertificatdegarantie 2 ans de garantie d usine sur les vices cach s Seuls les appareils accompagn s d un certificat de garantie d ment rempli et d un bon de caisse officiel avec la date d acha...

Page 10: ...laats de lucht venturie terug op de pomp 9 6 Bevestig de lucht venturie 9 aan de luchtdemper 4 gebruik hiervoor de meegeleverde blauwe slang 7 7 Plaats de skimmer in uw bioloog sump tank open de water...

Page 11: ...oopt Maar dit mag alleen op basis van 1 op 1 Een gescheiden afvalcollectie is beter voor het milieu en het helpt om bij de recycling de grondstoffen weer opnieuw te gebruiken Elke andere manier van af...

Page 12: ...ut purchase note no warranty Bewahren Sie den Kassenbon immer auf ohne Kaufbeweis keine Garantie Toujours garder le bon d achat sans bon aucune garantie Bewaar altijd het aankoopbewijs zonder bon geen...

Reviews: