background image

www.getbluelab.com

 

Care and use guide

 

I

n just one glance the Bluelab Guardian 

Monitor magically measures all 3 critical 

parameters for successful growth:

pH, conductivity AND temperature

Summary of Contents for Guardian Monitor

Page 1: ...www getbluelab com Care and use guide In just one glance the Bluelab Guardian Monitor magically measures all 3 critical parameters for successful growth pH conductivity AND temperature...

Page 2: ...WARNING Keep your pH probe tip wet at all times to avoid permanent damage...

Page 3: ...obe holder with suction cup 5 5V DC power supply 6 North American plug adaptor 7 NZ Australian plug adaptor 8 UK plug adaptor 9 European plug adaptor 10 4 x mounting fasteners 11 2 x cable ties 12 pH...

Page 4: ...aptor Select the appropriate mains plug adaptor for your country Connect the plug adaptor to the power supply 1 2 1 1 1 1 2 2 2 2 Option 1 Mounting keyholes top and bottom Option 2 Mounting holes top...

Page 5: ...n the Guardian Monitor is displaying conductivity in units of EC or CF If there is a decimal point present in the conductivity display the units are EC If there is no decimal point the units are CF Pr...

Page 6: ...reservoir but far enough down so the pH probe tip is in the solution The holder prevents damage to the pH probe from banging onto the side of the reservoir with movement of the solution Place the cond...

Page 7: ...Wait until the conductivity reading stabilizes The conductivity reading should be within 0 1 EC 1 CF 50 TDS or 70 ppm of the values in the table above If after testing the reading is lower than 2 77 E...

Page 8: ...could be wet inside temp displays or temp displays ur Over range temperature Under range temperature Solution 51 C 122 F Solution 0 C 32 F Conductivity temperature probe or Guardian Monitor faulty co...

Page 9: ...res replacing pH probes do not last forever They age through normal use and will eventually fail To ensure you receive a long life from your pH probe please read the instructions provided with it When...

Page 10: ...he instrument s brain or micro computer and a reading is then displayed If the information sent back from the probe is inaccurate due to probe surface contamination then the reading will be inaccurate...

Page 11: ...red by a separate 6 month guarantee The product will be repaired or replaced should it be found faulty due to component failure or faulty workmanship The faulty product should be returned to the point...

Page 12: ...on Manual Version 02 181211 00768_0811 Copyright 2011 all rights reserved Bluelab Corporation Limited guarantee The Bluelab product range all come with a free repair or replacement guarantee for your...