1.0    To operate

Using the Bluelab Commercial Truncheon

®

 Nutrient Meter (see Figure 1) to 

measure nutrient conductivity involves placing the probe sensor head in the 

solution, followed by measuring and reading conductivity values on the stem 

scale indicator light.

Figure 1. Bluelab Commercial Truncheon

®

 Nutrient Meter

Measure conductivity

Place probe into nutrient solution and take reading as 

indicated by the flashing lights.

Note:

 If the lights are dancing between two values, the reading 

is between those two values. Some example readings are 

shown in the table below:

Note: 

For very cold or very hot temperatures it will take 1-2 

minutes for the probe to reach solution temperature. To help 

decrease time taken to reach the solution temperature, place 

the probe in an area where there is a strong movement of 

solution, or stir solution with the probe.

Obtain another reading

To take another reading, simply place back in solution.

Clean probe

We recommend the probe be cleaned once every two 

weeks according to the Cleaning and Maintenance 

instructions. This can vary depending on frequency of use. 

Features

Fully waterproof

Battery operated

Auto on/off function

No buttons, switches or knobs

No calibration required

Daylight readable blue LED’s

Provided with EC, CF, ppm 500 and ppm 700 scales

English

2

1

2

3

Stem Scale

Probe

Value indicator light

Lights flashing 

between these 

EC values

Repeating pattern of 

flashing lights (EC)

Reading 

EC value

0.8 and 1.0

0.8 - 1.0, 

0.8 - 1.0,

 0.8 - 1.0

0.9

2.8 and 3.2

2.8 - 2.8 - 3.2, 

2.8 - 2.8 - 3.2

2.9

2.8 - 3.2 - 3.2, 

2.8 - 3.2 - 3.2

3.1

Summary of Contents for Commercial trunchelon nutrient meter

Page 1: ...To operate 2 Cleaning and maintenance 3 Battery replacement 3 Troubleshooting guide 4 Technical specifications 4 Conductivity and understanding the measuring scales 5 Bluelab measurement conversion ch...

Page 2: ...ature To help decrease time taken to reach the solution temperature place the probe in an area where there is a strong movement of solution or stir solution with the probe Obtain another reading To ta...

Page 3: ...film on the probe face with no beads of water If beading is present repeat the cleaning process Replace shroud 3 0 Battery replacement The Commercial Truncheon Meter is powered with 3 x AA type standa...

Page 4: ...eable batteries Truncheon Meter gives low readings Clean the probe Ensure unscented cleaner is used eg plain Jif Soft Scrub Liquid Vim Cif or Viss 5 0 Technical specifications Range 0 4 6 0 EC 200 300...

Page 5: ...resented as ppm by some meters A TDS reading of 50 means that there are 50 milligrams of dissolved solids in each litre of water 50ppm The ppm 700 scale as no relation to TDS so 70 milligrams of disso...

Page 6: ...1 3 1 3 13 650 910 1 4 1 4 14 700 980 1 5 1 5 15 750 1050 1 6 1 6 16 800 1120 1 7 1 7 17 850 1190 1 8 1 8 18 900 1260 1 9 1 9 19 950 1330 2 0 2 0 20 1000 1400 2 1 2 1 21 1050 1470 2 2 2 2 22 1100 154...

Page 7: ...or shipment of Product Product repaired or altered by parties other than Bluelab or its authorised agents Product with defaced missing or illegible serial numbers Products not purchased from Bluelab...

Page 8: ...ca Ph 909 599 1940 NZ Ph 64 7 578 0849 Fax 64 7 578 0847 Email support bluelab com get online Looking for specifications or technical advice Visit us online at bluelab com or facebook com getbluelab p...

Reviews: