Gas Inlet / Gas esté

INLET GAS PRESSURE MAX 1/2 PSIG (3.5 KPa)

200110-01B

03/15

WARNING:

 

Make sure Regulator Cap is in the appropriate position 

as shown in diagrams. Installation and service should be done by 

qualified service technician only.

Natural Gas

When using natural gas:

   Make sure the cap is installed in the propane/LP inlet of regulator.

   

Use thread sealant to assure there are no leaks.

Propane/LP Gas

When using propane/LP gas:

   Make sure the cap is installed in the natural gas (NG) inlet of regulator.

   

Use thread sealant to assure there are no leaks.

ADVERTENCIA:

 

Asegúrese la tapa del regulador esté en la posición adecuada, 

como se muestra en los diagramas. La instalación y reparaciones deben ser realizadas 

por un técnico de servicio calificado solamente.

 

Gas Natural 

Cuando se utiliza gas natural: 

   Asegúrese de que la tapa está instalado en el propano/LP entrada del regulador. 

   Utilice sellador de roscas para asegurar que no haya fugas. 

Propano/LP Gas 

Cuando se utiliza el gas propano / LP: 

    Asegúrese de que la tapa está instalado en la entrada de gas natural (GN) del regulador. 

    Utilice sellador de roscas para asegurar que no haya fugas.

Correct Pilot Flame Pattern

Incorrect Pilot Flame Pattern

NG

3-3.5" WC

Natural Gas

Shown

LP

8-11" WC

NG

3-3.5" WC

Natural Gas

Shown

LP

8-11" WC

1/2 Glass

Height

1/2 Glass

Height

Yellow

Tipping

Correct Burner Flame Pattern

Incorrect Burner Flame Pattern

LP

Blue Plunger

INSTALL SUPPLIED CAP IN FITTING

NOT BEING USED.

INSTALAR TAPA SUMINISTRADA MONTAJE NO SE UTILIZA.

NG

Yellow Plunger

This appliance may be installed in an aftermarket,* 

permanently located, manufactured (mobile) home, where 

not prohibited by local codes.

This appliance is only for use with propane or natural gas.

Field conversion by any other means including the use of 

a kit is not permitted.

WARNING: Make sure the supplied cap is 

installed in unused regulator fitting before 

connecting the correct gas supply line. 

WARNING: Do not use natural gas and 

propane gas together.

CAUTION: Two gas line installations at 

the same time are prohibited.
ADVERTENCIA: Asegúrese de que la línea 

no utilizado se conecta por primera vez 

antes de conectar la línea de suministro 

de gas correcta. 

ADVERTENCIA: No utilice el gas natural y 

el gas propano juntos.

PRECAUCIÓN: Dos instalaciones de 

líneas de gas al mismo tiempo están 

prohibidos.

FOR PROPANE GAS SUPPLY

PARA LA FUENTE DE GAS DEL PROPANE

CAUTION: The heater requires an external regulator to reduce 

the LP tank pressure to a maximum of 14" W.C. Never connect 

this product directly to the supply tank.
PRECAUCIÓN: El calentador requieres una externa regulador 

para reducir la presión del tanque de gas a un máximo de 14" 

W.C. Nunca conecte este producto directamente al tanque de 

suministro.

FOR NATURAL GAS SUPPLY

PARA LA FUENTE DE GAS DEL NATURAL

NOTICE: An additional gas regulator will be necessary if the 

local natural gas pressure exceeds the heater's rated maximum 

inlet pressure. If in doubt, contact the local gas utility. If natural 

gas inlet pressure exceeds 10" W.C., the safety pressure switch 

will activate. See owners manual for proper procedure to bypass 

the pressure switch.
AVISO: Un regulador de gas adicional será necesario si la 

presión del gas natural local excede de entrada nominal máxima 

del calentador presión. En caso de duda, póngase en contacto 

con la compañía de gas local. Si la presión de entrada de gas 

natural supera los 10" WC, el interruptor de presión de 

seguridad se activará. Consulte el manual del propietario para el 

procedimiento adecuado de derivación el interruptor de presión.

Procom Heating, Inc. U.S. Patent Information

This product may be covered by one or more of the following

United States patents:

8,915,239   8,851,065   8,764,436   8,757,202   8,757,139   8,752,541   

8,568,136   8,545,216   8,517,718   8,516,878   8,506,290   8,465,277   

8,317,511   8,297,968   8,281,781   8,241,034   8,235,708   8,152,515   

8,011,920   7,967,006   7,967,007   7,654,820   7,730,765   7,677,236   

7,607,426   7,434,447

Other patents pending.

TOLL-FREE Customer Care Number: 1-866-573-0674

Numero de Atención al Cliente GRATUITO: 1-866-573-0674

Visit our website for more information www.usaprocom.com

Visite nuestra página web para más informacion www.usaprocom.com

 WARNING: Never attempt to 

service stove while it is plugged 

in, operating, or hot. Burns and 

electrical  shock  could  result. 

Only a qualified service person 

should service or repair stove.

ELECTRICAL

DC 6V 1.5A

Adaptor

120V 60Hz

Power

Change

Assembly 

Reciever

(4 AA Batteries Required)

Valve

Red

Red

Yellow Black

Black

Red

Black

Pin and Socket Connector

LEARN

REMOTE OFF

ON

Power Change 

Assembly

Power Change 

Assembly

Verify proper operation after servicing. If any 

of the original wire as supplied with the stove 

must be replaced, it must be replaced with a 

wire of at least a 105º C temperature rating.

Figure 36 - Wiring Diagram

Summary of Contents for 170268

Page 1: ...lding Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be...

Page 2: ...ntilation section on page 6 of this manual WARNING FIRE EXPLOSION AND ASPHYXIATION HAZARD Improperadjustment alteration service maintenance or installation of this heater or its controls can cause dea...

Page 3: ...ol and those at high altitudes NATURAL AND PROPANE GAS Natural gas and propane gas are odorless An odor making agent is added to the gas The odor helps you detect a gas leak However the odor added to...

Page 4: ...eater with control knob at PILOT or ON locked positions Never set control knob between locked positions Poor combustion and higher levels of carbon monoxide may result 9 Do not use heater if any part...

Page 5: ...in the THERMO mode it automatically cycles the burner on and off to maintain a desired room tem perature LOCAL CODES Install and use heater with care Follow all local codes In the absence of local co...

Page 6: ...heater as the primary heat source Hood Logs Screen Heater Controls Behind Panel Screw Angle Iron QUALIFIED INSTALLING AGENCY Only a qualified agency should install and replace gas piping gas utilizat...

Page 7: ...ning appliances WARNING This heater shall not be installed in a room or space unless the required vol ume of indoor combustion air is provided by the method de scribed in the National Fuel Gas Code AN...

Page 8: ...ters add mois ture to the air Although this is beneficial installing heater in rooms without enough ventilation air may cause mildew to form too much moisture See Air for Combustion and Ventilation pa...

Page 9: ...han 6 B Clearances from the heater to the ceiling should not be less than 36 Note When heater is installed directly on carpeting tile or other combustible material other than wood flooring the heater...

Page 10: ...louvered slots on the front of the firebox Built in installation of this fireplace involves installing fireplace into a framed in enclosure This makes the front of the fireplace flush with wall If ins...

Page 11: ...earance to the sides and top of the firebox Combustible materials should never overlap the firebox front ASSEMBLING HOOD CAUTION Do not operate fireplace without hood in place Note Fireplace Hood is p...

Page 12: ...e threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves The installer must supply an external regula tor The external regulator wil...

Page 13: ...e Access into fireplace Cabinet Gas Regulator Inlet Connector Figure 12 Gas Connection Purchase the optional CSA design certified equipment shutoff valve from your dealer Equipment Shutoff Valve Groun...

Page 14: ...valve was connected 3 Pressurize supply piping system by either opening propane supply tank valve for propane gas or opening main gas valve located on or near gas meter for natural gas or using compr...

Page 15: ...contact with any log Withtheheatersettohigh check toseeifflamescontactanylog If so reposition logs according to the log installation instructions in this manual Flames contact ing logs will create soo...

Page 16: ...ts for safety Component Type of Battery Qty Ignitor AAA 1 Remote Control AAA 2 or 3 Remote Receiver AA 4 Note Quantity depends on model of remote Control Ignitor Unscrew ignitor cap and install a AAA...

Page 17: ...l system and any gas control which has been under water WARNING You must oper ate this heater with the screen in place Make sure screen is installed before running heater NOTICE Duringinitialoperation...

Page 18: ...h match To light pilot with match see Manual Lighting Procedure 7 Keep control knob pressed in for 30 sec onds after lighting pilot After 30 seconds release control knob Note If pilot goes out repeat...

Page 19: ...prepare the receiver box for learning use a pen or small screwdriver to gently press and hold the learn button until you hear 3 series of beeps 1 Place the slide switch on the receiver in the remote p...

Page 20: ...ce will be activated The transmitter has ON and OFF manual functions that are activated by pressing either button on the face of the transmitter When a button on the transmitter is pressed the word ON...

Page 21: ...the thermocouple This will cause the ther mocouple to cool which shuts the heater off If pilot flame pattern is incorrect as shown in Figure 31 turn heater off see To Turn Off Gas to Ap pliance page...

Page 22: ...or vacuum cleaner nozzle 5 Blow air into the primary air holes on the injector holder 6 In case any large clumps of dust have now been pushed into the burner Repeat steps 3 and 4 CARE AND MAINTENANCE...

Page 23: ...not available Any safety screen guard or barrier removed for servicing an appliance must be replaced prior tooperating the heater Figure 35 Pilot Inlet Air Hole CARE AND MAINTENANCE CABINET ODS PILOT...

Page 24: ...ch as Grounding Pin Grounding Means Metal Screw Cover of Grounded Outlet Box A B C Adapter Figure 36 Grounded Electrical Outlet ELECTRICAL WIRING Any electrical re wiring of this stove must be done by...

Page 25: ...OR PROPANE GAS SUPPLY PARA LA FUENTE DE GAS DEL PROPANE CAUTION The heater requires an external regulator to reduce the LP tank pressure to a maximum of 14 W C Never connect this product directly to t...

Page 26: ...ARNING Onlyaqualifiedservicetechnicianshouldserviceand repair heater Make sure that power is turned off before proceeding Turn off and let cool before servicing CAUTION Never use a wire needle or simi...

Page 27: ...rol knob to PILOT position 3 Fully press in control knob while pressing ignitor button 4 Continue holding down con trol knob Repeat igniting op eration until air is removed 5 Clean ODS pilot see Care...

Page 28: ...is too low 3 Gas regulator is damaged 1 Check burner for dirt and debris If found clean burner see Care and Maintenance page 22 2 Contact local gas supplier 3 Replace gas train Slightsmokeorodordur i...

Page 29: ...idue 1 Turn heater off when using furniture polish wax carpet cleaner or similar products Heater shuts off in use ODS operates 1 Not enough fresh air is avail able 2 Low line pressure 3 ODS pilot is p...

Page 30: ...www bluegrasliving com 163040 01A 30 PARTS MODEL B300RTN 1 6 8 9 2 3 5 4 7...

Page 31: ...ment Parts page 34 of this manual ITEM PART DESCRIPTION QTY 1 161338 01 Piezo Ignitor 1 2 161312 02 Receiver 1 3 161334 01 Remote Control 1 4 162520 01 6V DC Adapter 1 5 162521 01 Power Change Assembl...

Page 32: ...hen calling Customer Service or your dealer have ready Your name Your address Model and serial number of your heater How heater was malfunctioning Type of gas supply and Propane tank size Purchase dat...

Page 33: ...l at 1 866 762 4050 EQUIPMENT SHUTOFF VALVE For all models Equipment shutoff valve with 1 2 NPT tap OPTIONAL FAN KIT Optional fan kit part FIB100 The fan has 3 settings ON OFF Auto Existing Gas Line B...

Page 34: ...___________ ________________________________________________________________________ ________________________________________________________________________ __________________________________________...

Page 35: ...____________ ________________________________________________________________________ ________________________________________________________________________ _________________________________________...

Page 36: ...arranty covers the cost of part s required to restore this product to proper operating condition and an allowance for labor when provided by a Bluegrass Living Authorized Service Center or a provider...

Reviews: