Directions
1
Confirm that pump is in the OFF position
2
Press 4-20mA Input button
1
7.1 Selecting 4-20mA input mode
Directions
1
Confirm that pump is in the OFF position.
2
Press and hold 4-20mA Input button.
3
MIN mA light will illuminate. Use arrow
keys to toggle min mA value for the pump
to operate at
4
Press 4-20mA Input button for MIN %
Speed light to illuminate
5
Use arrow keys to toggle MIN % Speed
value for the pump to operate.
6
Press 4-20mA Input button for MAX mA
light to illuminate.
7
Use arrow keys to toggle MAX mA value
for the pump to operate.
8
Press 4-20mA Input button for MAX %
Speed light to illuminate.
9
Use arrow keys to toggle MAX % Speed
value for the pump to operate.
10
Press and hold 4-20mA Input button to exit
programming mode.