OPERATING MODE 5 - Batch Mode
In this mode, the pump’s ‘motor speed’ and ‘on time’ is configured to be initiated
by a single pulse or up to 1,999 pulses.
You will configure the pump in the following order:
a.
Select the
% SPEED
.
(1% to 100%)
b.
Select the pump
ON
time.
(0.1 to 199.9 and select units: seconds (
SEC
) or minutes (
MIN
)
c.
Select the amount of pulses to receive to trigger the pump.
(1 pulse up to 1999 pulses)
4
Set the pump for mode 5
.
Press the MODE button until
MODE 5
is shown on the LCD display.
The
% SPEED
and
Hz
icon will light.
The large
LCD
will indicate the current
motor speed or the Hz input value.
4
Enter the programming mode.
While
MODE 5
is displayed, press and
hold the
MODE
button for more than
two seconds.
Blinking
ARROW’s
will point to the
word
PROGRAM
and
MINIMUM
tm
CHEM-PRO
C3V | Diaphragm Metering Pump
Made in the USA
MODE
PRIME
Program
Minimum
Maximum
Blue-White Ind.
IP66
NEMA 4X
Mode 5
MODE
A blinking
ARROW
will point to the word
PROGRAM
and the
% SPEED
icon
will blink indicating the program mode is activated and the
% SPEED
value
is ready to be programed.
MODE
4
Enter the motor speed
. (1% to 100%)
Press the
DOWN
button to select the digit to program. The digit will blink
when selected. (Moves to the next digit to the right.)
Press the
UP
button to change the selected digit.
Repeat until all digits are programmed.
Press the
MODE
button. The
% SPEED
icon will stop blinking and the
SEC
or
MIN
icon will blink indicating the pump
ON-time
value is ready to be
programmed.
4
Enter the pump ON-time
. (0.1 to 199.9 seconds or minutes)
Press the
DOWN
button to select the digit to program. The digit will blink
when selected. (Moves to the next digit to the right.)
Press the
UP
button to change the selected digit.
Repeat until all digits are programmed.
MODE
MODE
MODE
Repeat until all digits are programmed.
Press the
MODE
button. Programming is complete.
To exit the programming mode, press and hold the
MODE
button for more
than two seconds. The
PROGRAM
arrow will disappear.
Mode 4 Programming Examples
0%
25%
50%
75%
100%
P
u
m
p
O
u
tp
u
t
M
o
to
r
S
p
e
e
d
Hz input
from external source
0%
Output
Example 1
0 Hz will result in a pump output of 0.0%
1000 Hz will result in a pump output of
0.0%
0
1000
90%
Output
200
400
600
800
Example 3
0 Hz will result in a pump output of
90.0%
1000 Hz will result in a pump output of
0.0%
Example 3
0 VDC will result in a pump output of
0.0%
800 Hz will result in a pump output of
50.0%
0%
25%
50%
75%
100%
P
u
m
p
O
u
tp
u
t
M
o
to
r
S
p
e
e
d
Hz input
from external source
50.0%
Output
0
1000
0.0%
Output
200
400
600
800
200
400
600
0%
25%
50%
75%
100%
P
u
m
p
O
u
tp
u
t
M
o
to
r
S
p
e
e
d
Hz input
from external source
100%
Output
0
800
0%
Output
1000