Remote
Local
% Speed
RPM
mA
Signal
RUN MODES
DISPLAY
Remote
Start / Stop
FVS
Manual
Adjust
1. Press & Hold mA Input to Setup
2. Use Arrow Keys to Adjust
3. Press mA Input to Toggle Next
4. Press & Hold mA Input to Exit
MIN mA
MIN % Speed
MAX mA MAX % Speed
4-20mA
Input
8.0
Programming FVS (Flow Verification Sensor)
Proper eye and skin protection must be worn when installing and servicing the pump.
CAUTION
!
Directions
1
Confirm that pump is in the OFF position
2
Press and hold FVS button
3
Toggle up/down arrow until desired
trigger time is shown (seconds)
4
Press and hold FVS button to set
1
2
NOTE: Alarm Delay Time range is 1-20 seconds
Risk of electric shock – cord connected models are supplied with a grounding conductor and
grounding-type attachment plug. To reduce risk of electric shock, be certain that it is connected only
to a properly grounded, grounding-type receptacle.
>
Use the voltage for which the power cord is rated.
>
Do not strap together control (input/output) cables and power cables.
>
When there is a power interruption, the pump, which has an auto-restart feature, will restore the pump to the
operating state it was in when the power was lost.
>
POWER: 115V60Hz (0.6A max.), 220V50Hz (0.3A max.), 230V60Hz (0.3A max.), 230V50Hz (0.3A max.),
240V50Hz (0.3A max.)
NOTE
: Contact a licensed electrician when there is doubt regarding the electrical installation.
Electrical connections and grounding (earthing) must conform to local wiring codes.
9.0
POWER CONNECTIONS
Ensure to connect the pump to the proper supply voltage. Using the incorrect voltage will damage
the pump and may result in injury. The voltage requirements is printed on the pump serial label.
WARNING
Page 13
3
WARNING
WARNING
®
CHEM-FEED MD1