Discharge Tube
(Opaque P.E.)
Outlet Adapter
Tube Nut
Inlet Adapter
Tube Nut
Suction Tubing
(clear PVC)
Pump Head
FootValve
FootValve Assembly
Must be installed in
a vertical position.
FootValve Assemble
Ceramic
Weight
Suction Tubing
Suction Tubing
Clamp
Lock Nut
Footvalve Adapter
O-Ring
Ceramic Ball
O-Ring
O-Ring
Footvalve Body
Footvalve Strainer
FIG. 4.8 C-600P
FootValve Assy.
C-600P
PumpHead
C-600HV
PumpHead
C-600HV
FootValve Assy.
4.5
Injection/Check Valve Fitting Installation
-
The Injection/Check valve fitting is designed
to install directly into either 1/4” or ½” female
pipe threads. This fitting will require periodic
cleaning, especially when injecting fluids that
calcify such as sodium hypochlorite. These
lime deposits and other build ups can clog
the fitting increasing the back pressure and
interfering with the check valve operation.
Install the Injection/Check valve directly into
the tee fitting. Do not install the fitting into a
pipe stud and then into the tee. The solution
must inject directly into the flow stream.
Use PTFE thread sealing tape on the pipe
threads. Push the opaque outlet (discharge)
tubing onto the compression barb of the
Injection/Check valve fitting. Use the tube
nut to secure the tube. Hand tighten only.
FIG. 4.9 C-600P
INJECTION/CHECK VALVE
TEE INSTALLATION AND EXPLODED VIEW
CAUTION - TO ENSURE CHEMICAL DOES NOT SYPHON THROUGH THE
PUMP, INSTALL THE INCLUDED SPRING-LOADED INJECTION CHECK-VALVE
OR A SUITABLE ANTI-SYPHON VALVE.
Page 8
Page 9
C-600
C-600
4.4
How To Install the Tubing and Fittings
Inlet Tubing -
Locate the inlet fitting of the pump head. Remove the
tube nut. Push the clear PVC suction tubing onto the compression barb
of the fitting. Use the tube nut to secure the tube. Hand tighten only.
Footvalve/Strainer
-Trim the inlet end of the suction tubing so that the
strainer will rest in a vertical position, approximately one inch from the
bottom of the solution tank. This will prevent sediment from clogging the
strainer. Loss of prime may occur if the footvalve is permitted to lay on
the bottom of the solution tank in a horizontal position. Slip the ceramic
weight over the end of the suction tube. Press the footvalve/strainer into
the end of the tube. Secure the ceramic weight to the strainer. Drop the
strainer into the solution tank.
Outlet Tubing -
Locate the outlet fitting of the pump head, Remove the
tube nut. Push the rigid outlet (discharge) tubing onto the compression
barb of the fitting. Use the tube nut to secure the tube. Hand tighten
only.
Trim the other end of the outlet tube leaving only enough slack to
connect it to the Injection/Check valve Fitting . Increasing the length of
the outlet tube increases the back pressure at the pump head, particu-
larly when pumping viscous fluids.
Keep the inlet and outlet tubes as short as possible.
FIG. 4.6 WIRING DIAGRAM - FIXED TIMERS
CAUTION: PROPER EYE AND SKIN PROTECTION MUST BE WORN
WHEN INSTALLING AND SERVICING THE PUMP
Earth Ground (green)
120VAC
HOT
LOAD
220/230 VAC
Hot
Power
Cord
AC
MOTOR
Timer
Board
Neutral
Hot
Cycle Adjustment
Potentiometer
Common