background image

5300 Business Drive

Huntington Beach, CA 92649

USA

Phone:

 714-893-8529     

FAX:

 714-894-9492

E-mails:

 [email protected]  

or

  [email protected]

    www.blue-white.com 

DIAPHRAGM INJECTOR

MODEL C-600P & C-600HV

Blue-White

Industries, Ltd.

®

Summary of Contents for C-600HV

Page 1: ...rive Huntington Beach CA 92649 USA Phone 714 893 8529 FAX 714 894 9492 E mails sales blue white com or techsupport blue white com www blue white com DIAPHRAGM INJECTOR MODEL C 600P C 600HV Blue White...

Page 2: ...5 4 Measuring the pump s output volumetric test 10 6 0 How to maintain the metering pump 11 6 1 Routine inspection and cleaning 11 6 2 How to clean the metering pump 11 7 0 C 600HV Parts List 12 7 1...

Page 3: ...36A max 24V60Hz 45 Watts 3 4A max 12VDC 3A max 24VDC 1 5A max Dimensions 6 1 2 H x 6 1 2 W x 5 3 4 D C 600P 7 H x 6 3 4 W x 6 1 8 D C 600HV Weight 8 lb 3 0 Features Double ball ceramic check valves P...

Page 4: ...Page 4 C 600 5 0625 134 9mm 0 1 2 3 4 5 6 75 171 5mm 6 25 158 8mm C 600P C 600HV 0 1 2 3 4 5 6 75 171 45mm 6 125 155 5mm 7 177 8mm 3 1 Pump Dimensions...

Page 5: ...t the pump off to the side or at a lower level than the chemical container Mounting the pump lower than the chemical container will gravity feed the chemical into the pump This flooded suction install...

Page 6: ...Page 6 C 600 WEATHER RESISTANT NPT Injector Suction Tube vertical Chemical Container Pumping unit Discharge Tube Stud 0 0 1 1 2 2 3 3 4 4 5 5 Masonry Stud Mount WALL MOUNTING 4 2 Typical Installation...

Page 7: ...k of electric shock be certain that a grounding conductor is connected to the green grounding screw located in the junction box FIG 4 5 WIRING DIAGRAM STANDARD MODELS AC MOTOR INPUT VOLTAGE 115V 60Hz...

Page 8: ...strainer into the end of the tube Secure the ceramic weight to the strainer Drop the strainer into the solution tank Outlet Tubing Locate the outlet fitting of the pump head Remove the tube nut Push...

Page 9: ...ially when injecting fluids that calcify such as sodium hypochlorite These lime deposits and other build ups can clog the fitting increasing the back pressure and interfering with the check valve oper...

Page 10: ...is sealed in the pump head keeping the valves dry to aid in priming If the valves have dried or priming is difficult due to back pressure do the following 1 Remove the opaque discharge tubing from th...

Page 11: ...components for signs of leaking swelling cracking discoloration or corrosion Replace worn or damaged components immediately Cracking crazing discoloration and the like during the first week of operati...

Page 12: ...sher 1 17 76000 514 H V Aluminum Spacer 1 18 C 3301 Motor Mount 2 19 C 624 Screw 10 32X1 2 4 20 C 3325 Cam Set 1 21 C 3304 Yoke and Bearing 1 22 90011 155 Screw 6 32X3 8 1 23 90002 201 Cam Cover 1 24...

Page 13: ...Page 13 C 600 25 27 25 28 29 32 33 34 30 31 26 1 2 3 2 7 6 5 4 9 7 8 5 10 2 11 12 13 15 16 20 21 24 18 19 3 2 14 17 22 23 8 1 C 600HV Exploded View...

Page 14: ...box Assembly 14 RPM 1 C 618P 30 Gearbox Assembly 30 RPM 1 C 618P 45 Gearbox Assembly 45 RPM 1 C 618P 60 Gearbox Assembly 60 RPM 1 C 618P 125 Gearbox Assembly 125 RPM 1 C 618P 250 Gearbox Assembly 250...

Page 15: ...Page 15 C 600 4 4 10 9 8 22 6 3 5 15 28 16 15 14 13 26 27 12 11 23 25 25 T I Anti siphon valve fitting Threaded Anti siphon valve N P T Optional 7 2 3 1 17 18 19 20 24 21 9 1 C 600P Exploded View...

Page 16: ...ccompanied by the sales invoice or receipt to obtain warranty coverage The warranty status of the pump will be verified by Blue White or a factory authorized service center Please be advised injection...

Reviews: