No message on display. Power has
been cut off to the spa.
The control panel will be disabled until
power returns. Spa settings will be
preserved until next power up.
Temperature unknown.
After the pump has been running for 2
minutes, the temperature will be displayed.
“Overheat” - The spa has shut
down. * One of the sensors has
detected 118°F/47.8°C at the
heater.
DO NOT ENTER THE WATER. Remove the
spa cover and allow water to cool. Once the
heater has cooled, reset by pushing any
button. If spa does not reset, shut off the
power to the spa and call your dealer or
service organization.
“Overheat” - The spa has shut down.
One of the sensors has detected
110°F/43.5°C.
DO NOT ENTER THE WATER. Remove the
spa cover and allow water to cool. At
107°F/41.7°C, the spa should automatically
reset. If spa does not reset, shut off the
power to the spa and call your dealer or
service organization.
Spa is shut down. * The sensor that
is plugged into the Sensor “A” jack
is not working
If the problem persists, contact your dealer
or service organization. (May appear
temporarily in an overheat condition)
Spa is shut down. * The sensor that
is plugged into the Sensor “B” jack
is not working.
If the problem persists, contact your dealer
or service organization. (May appear
temporarily in an overheat condition)
Sensors are out of balance. If alternating
with spa temperature, it may just be a
temporary condition. If flashing by itself, spa
is shut down. *
If the problem persists, contact your dealer
or service organization.
A
significant
difference
between
temperature sensors has been detected.
This could indicate a flow problem.
If the water level is normal, make sure all pumps
have been primed. If problem persists, contact
your dealer or service organization.
Persistent low flow problems. (Displays on
the fifth occurrence of “ “ message within
24 hours.) Heater is shut down, but other
spa functions continue to run normally.
Follow action required for message. Heating
capability of the spa will not reset automatically;
you may press any button to reset.
Possible inadequate water, poor flow, or air
bubbles detected in the heater. Spa is shut
down for 15 minutes.
If water level is normal, make sure all pumps have
been primed. Press any button to reset. This
message will reset within 15 minutes. If problem
persists, contact your dealer or service organization.
Inadequate water detected in heater. (Displays on
third occurrence of message.) Spa is shut
down.*
Follow action required for message. Spa will
not automatically reset. Press any button to reset
manually.
“Ice” – Potential Freeze condition detected
No action required. All equipment will automatically
activate regardless of spa status. The equipment stays
on 4 minutes after the sensors detect that the spa
temperature has risen to 45°F/7.2°C or higher. An
optional freeze sensor may be added to protect against
extraordinary freeze conditions. Auxiliary freeze sensor
protection is advisable is colder climates. See your
dealer for details.
*-
Even when spa is shut down, some equipment
will turn on if freeze protection is needed.
Diagnostic Messages
Message
Meaning
Action Required