507768-02B
Page 44 of 56
Issue 1904
Unit Start-Up
FOR YOUR SAFETY READ BEFORE OPERATING
Do not use this furnace if any part has been underwater.
A flood-damaged furnace is extremely dangerous.
Attempts to use the furnace can result in fire or explosion.
Immediately call a qualified service technician to inspect
the furnace and to replace all gas controls, control
system parts, and electrical parts that have been wet or
to replace the furnace, if deemed necessary.
WARNING
Danger of explosion. Can cause injury or
product or property damage. Should the gas
supply fail to shut off or if overheating
occurs, shut off the gas valve to the furnace
before shutting off the electrical blower
deck, before performing any service
procedure.
WARNING
Before attempting to perform any service or
maintenance, turn the electrical power to unit OFF at
disconnect switch.
CAUTION
BEFORE LIGHTING
the unit, smell all around the furnace
area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the floor.
The gas valve on the unit is equipped with a gas control
switch (lever). Use only your hand to move switch. Never
use tools. If the switch will not move by hand, do not try to
repair it. Force or attempted repair may result in a fire or
explosion.
Placing the Furnace into Operation
This furnace is equipped with an automatic hot surface
ignition system. Do not attempt to manually light burners
on this furnace. Each time the thermostat calls for heat, the
burners will automatically light. The ignitor does not get hot
when there is no call for heat on these units.
Figure 68. Integrated Control
(Automatic Hot Surface Ignition System)
Terminal Designations
120 HUM
Humidifier (120 VAC)
LINE
Input (120 VAC)
XFMR
Transformer (120 VAC)
CIRC
Indoor Blower (120 VAC)
EAC
Electronic Air Cleaner (120 VAC)
COOL
Blower - Cooling Speed (24 VAC)
HEAT
Blower - Heating Speed (24 VAC)
FAN
Blower - Fan Speed (24 VAC)
PARK
Dead terminals to park all speed taps
NEUTRALS
Neutral Terminals (120 VAC)
FS
Flame Sense
24 COM
Common (24 VAC)
HUM 24
Humidifier (24 VAC)
Summary of Contents for BG961UHE
Page 3: ...507768 02B Page 3 of 56 Issue 1904 Figure 1 Parts Arrangement ...
Page 22: ...507768 02B Page 22 of 56 Issue 1904 Figure 25 Figure 26 ...
Page 37: ...507768 02B Page 37 of 56 Issue 1904 Figure 59 Trap Drain Assembly Using 1 2 PVC or 3 4 PVC ...