7
Drain Water
To achieve the maximum cooling efficiency, the
airconditioner is designed to splash the condensation
water on the condenser coil.
In order to avoid the splashing sound, an external
drain can be provided by using the following
procedure. This may however cause a small loss of
performance.
1.
Slide out the chassis from the cabinet
2.
Remove the rubber plug from the body base
plate.
3.
Install the drain pan at the corner of the cabinet
with 2 screws.
4.
Connect the drain hose to the outlet on the
drain pan bottom.
5.
Slide the chassis into its original place in the
cabinet.
Relocation
To relocate the airconditioner, please contact your
dealer. Relocation should be carried out only under
the direction of authorised professional technician.
Electric Wiring
–
Ensure reliable earthing.
–
Use an exclusive circuit
–
Do not use removable socket which could lead
to poor contact.
–
Install MCB in the AC circuit to suit the capacity.
Recommended: 16A
–
The fixed wiring should be more than 2.5sq.mm.
–
Use approved voltage stabiliser, with a minimum
capacity of 3kVA.