22 | www.blueskyoutdoorliving.com
LEAK TEST
WARNING
Check all connections and fittings for leaks using soapy water. Never use
a flame.
Perform all leak tests outdoors. Before performing a leak test, extinguish
all open flames. NEVER leak test when smoking.
Do not use the heater until all connections have been leak tested and do
not leak.
Hose/Regulator
Connection
Regulator/Cylinder
Connection
1.
Make 2–3 oz. of leak check solution (one part liquid dishwashing detergent
and three parts water).
2.
Apply several drops of solution where the hose attaches to regulator.
3.
Apply several drops of solution where the regulator connects to cylinder.
4.
Make sure all patio heater and light valves are OFF.
5.
Turn the cylinder valve ON.
IF BUBBLES APPEAR AT ANY CONNECTION, THERE IS A LEAK.
If there is a leak:
1.
Turn the cylinder valve OFF.
2.
If the leak is at hose/regulator connection: tighten connection and perform
another leak test. If bubbles continue appearing, the hose should be
returned to the place of purchase.
3.
If the leak is at regulator/cylinder valve connection: disconnect, reconnect,
and perform another leak check. If you continue to see bubbles after
several attempts, the cylinder valve is defective and should be returned to
cylinder’s place of purchase.