BATTERY CHARGE PARAMETERS Menu 

 
 

 

From Setup menu

 

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 

 
 
 
 
 

FIGURE 5  

 
 
 
 
 
 

SET ACCEPT CHG   
14.4V       SEL

 

 

Sets Absorption charge voltage setpoint.  
Range 10.0 to 80.0V. 

SET FLOAT CHG   
13.4V       SEL

 

 

Sets Float charge voltage setpoint.  
Range 10.0 to 80.0V. 

SET ACCEPT TIME 
 2.0HRS     SEL

 

SET FLOAT CURENT 
 1.5A/100AH SEL

 

 

Sets Float Transition Current. Range 0.1 to 10.0A per 100 AH. A setting of 
0 (zero) disables function such that full charge is based on Absorption 
charge time only. See charge controller operators manual. 

SET EQUALIZ CHG   
15.2V       SEL

 

 

Sets Equalize voltage setpoint.  
Range 10.0 to 80.0V. 

SET EQUALIZ TIME 
 2.0HRS     SEL

 

 

Sets Equalize time. 
Range 0.5 to 10 hours. 

SET AUTO EQUALIZ 
 30DAYS     SEL

 

 

Sets days between automatic Equalize. Range is 10 to 400 days. Fully 
MANUAL equalization is selected by a setting of less than 10 days. 

SET T-COMP SLOPE 
-5.00mV/C/C SEL

 

 

Sets charge voltage temperature compensation factor.  
Range is -0.00 to -8.00mV/

C/cell. 

Sets Absorption charge time. 
Range 0.0 to 10.0 hours. 

Summary of Contents for IPN ProRemote

Page 1: ...lue Sky Energy Inc 2017 430 0019 G EN FCC CFR 47 Part 15 Subpart B This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operations CONFORMS TO EN 61326 1 2006 EN 60335 1 2002 A11 2004 A1 2004 EN 6...

Page 2: ... 10 As Shipped Factory Default Settings 10 Restoring Factory Default Settings 10 Battery Amp hour Rating 10 Charge Efficiency and Charge Efficiency Mode 10 Self Discharge Rate 10 Float Transition Current 11 Current Shunt 12 Current Shunt Signal Wiring 12 Resetting Current Shunt Zero 12 Charge Controller Connection 12 Mounting 13 TROUBLESHOOTING GUIDE 13 SPECIFICATIONS 15 FIVE YEAR LIMITED WARRANTY...

Page 3: ...or other electrical part that may cause explosion i Remove personal metal items such as rings bracelets and watches when working with a lead acid battery A lead acid battery can produce a short circuit current high enough to weld a ring or the like to metal causing a severe burn j Remove all sources of power photovoltaic and battery before servicing or installing 4 DISPLAY LOCATION INSTALLATION a ...

Page 4: ...rameter setting screen causes the parameter to go to the next value or increases a numeric setting Pressing BACK while holding NEXT pressed in a parameter setting screen decreases numeric settings If BACK is pressed without holding NEXT pressed BACK will perform it s normal function and exit the parameter setting screen To decrease a setting press and hold NEXT then additionally press and hold BAC...

Page 5: ...e not 100 efficient at receiving charge Additionally batteries loose charge on their own due to self discharge which is periodically computed and added to the amp hours from full counter Self discharge changes with battery temperature and will be corrected for temperature if the accompanying charge controller includes a battery temperature sensor Counting amp hours into and out of the battery and ...

Page 6: ...QUALIZE NOW AT AT 15 4V SEL ENTER ADVANCED DSPLY SETUP SEL EQLZ 120min LEFT AT 15 4V CLR LOAD CONTROL OUTPUT ON Sum of input and output current for all charge controllers on the IPN network Total battery amp hours from full Amp hours from full are used to compute remaining battery capacity which is shown as Percent Remaining and as a Bar Graph Dashes are shown until the battery is fully charged by...

Page 7: ...cleared MIN BAT VOLTS 11 9V CLR TOTAL CHG AMP HR 1980AH CLR Captures total output amp hours of all charge controllers on the IPN network since last cleared LIFETIME BAT AH 9876543AH CLR Serves as battery odometer capturing total discharge amp hours since last cleared Value saved to non volatile memory once per day BAT TEMPERATURE 25C 77F 1980AH CLR Shows present battery temperature if optional sen...

Page 8: ...43AH CLR Corrects for zero offset in net battery current display CAUTION Be certain shunt signal is a true zero before performing this function or inaccurate battery current amp hour readings will result See Resetting Current Shunt Zero section of manual before proceeding With charge efficiency set to 94 battery is expected to retain 94 amp hours for each 100 amp hours of charge With charge effici...

Page 9: ...0 AH A setting of 0 zero disables function such that full charge is based on Absorption charge time only See charge controller operators manual SET EQUALIZ CHG 15 2V SEL Sets Equalize voltage setpoint Range 10 0 to 80 0V SET EQUALIZ TIME 2 0HRS SEL Sets Equalize time Range 0 5 to 10 hours SET AUTO EQUALIZ 30DAYS SEL Sets days between automatic Equalize Range is 10 to 400 days Fully MANUAL equaliza...

Page 10: ...isplay Setup select screen LAST FULL CHARGE 10 DAYS AGO Press SELECT for 4 seconds to move to the top of the Advanced Display menu ENTER SETUP MENUS SEL Press NEXT 8 times to move down to Enter Setup Menus select screen SET BAT AMP HRS 220AH SEL Press SELECT for 4 seconds to move to the top of the Setup Menu SETTING AMP HRS 220AH SET Press SELECT for 4 seconds to move to Battery Amp Hours paramete...

Page 11: ...estored except for auxiliary output settings in slave charge controllers Battery Amp Hour Rating The amp hour setting is used by both the Remaining Battery Capacity function and Advanced Charge Control The setting should be the total published 25 C 20hr rate amp hour rating of the total battery bank For systems with more than one battery battery amp hours add when batteries are placed in parallel ...

Page 12: ...n Current setting Float Current in the Battery Charge Parameters menu of 1 5 amps per 100 amp hours of battery capacity is suitable for most batteries With the factory default Battery Amp Hour setting of 220 amp hours the battery would be considered fully charged when net battery charge current decreases to less than 3 3 amps while at the Absorption voltage setpoint To assure that net charge curre...

Page 13: ...mal electronic component aging A Reset Current Shunt Zero function is provided to compensate for zero offset and provide an accurate zero reading CAUTION It is critically important that a Reset Current Shunt Zero function not be performed without first providing a true zero current signal to the IPN ProRemote This is accomplished by temporarily placing both shunt sensing wires at the current shunt...

Page 14: ...OMMENDED CABLE LENGTH FEET METERS 30 AWG 45 13 7 28 AWG 73 22 2 26 AWG 117 35 7 24 AWG 187 57 0 22 AWG 295 89 9 20 AWG 475 144 8 TABLE 3 MOUNTING CAUTION The unit is designed to mount into a standard US duplex wall mount box It is not watertight and must be protected from rain snow and excessive moisture DETAILED DIMENSIONAL DRAWING FIGURE 8 TROUBLESHOOTING GUIDE SYMPTOM PROBABLE CAUSE ITEMS TO EX...

Page 15: ...ise generating wiring Confirm that with backlight ON and with highest possible charge or discharge current flowing in system voltage difference between COM test point and SHUNT on the back of the IPN ProRemote is less than 1 0V at all times with less voltage drop being better Correct wiring as necessary Consider not using backlight Perform Reset Current Shunt Zero function exactly as described in ...

Page 16: ...t accompany the product to obtain warranty repairs 3 This limited warranty does not apply to and future warranty shall become void for any product or part thereof damaged by a alteration disassembly or application of a foreign substance b repair or service not rendered by a BSE authorized repair facility c accident or abuse d corrosion e lightning or other act of God f operation or installation co...

Reviews: