27
Gas Type Labels
On completion of the gas conversion, replace gas type labels located at:-
- The rear of the unit, above the gas connection.
- Beside the rating plate.
Commissioning
Before leaving the converted installation;
1.
Check all gas connections for leakages using soapy water or other gas detecting equipment.
2.
Check the following functions in accordance with the operating instructions specified in the
'Operation' section of this manual.
•
Light the Pilot Burners.
•
Light the Main Burners.
•
Check the Low Fire Burner operation.
•
Check the High Fire Burner operation.
•
Ensure that all the controls operate correctly.
•
Ensure that the operating pressure remains correct.
3.
Ensure any adjustments done to components that have the adjustments / settings sealed (e.g. paint
sealed) are re-sealed.
4.
This manual must be kept by the owner for future reference and a record of
Date of Purchase,
Date of Installation
and
Serial Number of Appliance
should be recorded and kept with this
manual. (These details can be found on the Rating Plate attached to the underside of the R/H side,
front Cooktop lower trim, for Bench, Cabinet Base and Leg Stand Models. For the Refrigerated Base
Models, the Rating Plate is located inside the right hand front panel and can be viewed through the
upper grille. Refer to the 'Gas Connection' section).
NOTE: If for some reason it is not possible to get the appliance to operate correctly, shut off the
gas supply and contact the supplier of this appliance.
Gas Conversion and Specifications
WARNING:
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.