Blue Sea BatteryLink 7603 User Manual Download Page 12

980022770 Rev.003

[email protected]

www.bluesea.com

For the following equipment:

Product type: Battery charger

Type designation: BatteryLink Charger: 7603, 7604

Manufacturer: Blue Sea Systems, Inc.

Address: 425 Sequoia Drive

 

Bellingham, WA

 

98226 USA

 

Phone: 001.360.738.8230

Herewith it is confirmed to comply with the requirements set out in the council directive, 2006/95/EC for 

electrical equipment used within certain voltage limits, the EMC directive 2004/108/EC , and the Recre-

ational Craft Directive 2013/53/EU.

Safety:  IEC60335-1:2010+A1

 

IEC60335-2-29:2002+A1+A2

 

EN60335-1:2010+A1

 

EN60335-2-29:2002+A1+A2

EMC: Emission: 

EN 55014-1:2006/A1:209, /A2:2011

 

Radiated emission

 

Conducted emission

 

EN61000-3-2 Harmonics

 

EN61000-3-3 Voltage fluctuations and flicker

 Immunity: 

EN 55014-2:1997/A1:2002, /A2:2008

 

EN61000-4-2 Electrostatic discharge

 

EN61000-4-3 RF electromagnetic field

 

EN61000-4-4 Fast transient

 

EN61000-4-5 Surges

 

EN61000-4-6 RF conducted disturbances

 

EN61000-4-11 Voltage dips and interruptions

Ignition Protection:

 

ISO 8846 (ed. 1)

 

The notified body HPi Verification Services Ltd (NB 1521) performed type examination to verify  

 

compliance with the above ignition protection standard, and issued the certificate 

 

HPiVS/R1168-001-l-01.

The undersigned hereby declare that the equipment specified above conforms to the above directives 

and standards

Bellingham

 

2016-04-1

Blue Sea Systems, Inc.

........................................................

David Johnson, Senior Vice President of Marine and Mobile

EC DECLARATION OF CONFORMITY

Summary of Contents for BatteryLink 7603

Page 1: ...ctions for the BatteryLink Chargers This User Manual describes the product mentioned herein at the time of its publication Specifications and performance are subject to change at the discretion of Blu...

Page 2: ...ryLink Charger is marked as ignition protected for operation in a small craft gasoline engine space HOWEVER Connection or disconnection of any electrical cables may cause sparks which could ignite fla...

Page 3: ...re battery switch is in the OFF position before making or breaking any connections to the battery If no battery switch is installed ensure all accessories are OFF 14 Charger should be grounded to redu...

Page 4: ...hardware Hex recesses accept 10 3 8 socket size nuts NOTE Mounting holes are not symmetrical please see dimensioned drawing DC output battery positive connections 1 4 20 studs accept 1 4 or M6 ring te...

Page 5: ...the charger output and ACR are turned off to conserve energy and the battery voltages are monitored If loads or self discharge on either battery cause the voltage to drop to 12 9V the charger enters...

Page 6: ...er ACR STATUS Green solid Combined ACR closed Double blink SI present ACR open Off Battery voltages below threshold ACR open REMOTE LED CHARGE STATUS DC Power Solid Combined ACR closed Off Separated A...

Page 7: ...ttach the sensor in the center of the long side of the battery If multiple batteries are in a battery bank attach the sensor in the center between multiple batteries When external circumstances could...

Page 8: ...ar GROUND Battery Temp Sensor Start Isolation Remote LED NEG NEG BATTERY BATTERY BUS BUS DC Negative DC Positive Start Battery Auxiliary Battery INPUT 230V AC BatteryLink Charger Dual Circuit Plus Bat...

Page 9: ...p Sensor Start Isolation Remote LED NEG NEG BATTERY BATTERY BUS BUS OPTIONAL REMOTE INDICATOR 2A FUSE Optional DC Negative DC Positive Start Battery Auxiliary Battery INPUT 230V AC BatteryLink Charger...

Page 10: ...ACR Intermittent Rating 5 min 115A ACR Combine Voltage 13 0V 2 min 13 5V 30 sec ACR Open Voltage 12 35V 10 sec 12 75V 30 sec Operating Current no AC power 10mA ACR open 60mA ACR closed Maximum Cable S...

Page 11: ...COVER REMOVED 0 0mm 0in 142 8mm 5 62in 143 7mm 5 66in 0 0mm 0in 10 6mm 42in 84 7mm 3 34in THIS VIEW SHOWN WITH COVER REMOVED FOR OPTIMAL PERFORMANCE MOUNT VERTICALLY AS SHOWN IN A WELL VENTILATED AREA...

Page 12: ...1 209 A2 2011 Radiated emission Conducted emission EN61000 3 2 Harmonics EN61000 3 3 Voltage fluctuations and flicker Immunity EN 55014 2 1997 A1 2002 A2 2008 EN61000 4 2 Electrostatic discharge EN610...

Reviews: