Installation
(continued)
Apply 12V DC label, and circuit labels. Remove fuse seal and check that
appropriately rated fuses are installed for each device.
6. Make connections as per diagram at right.
a. C 12V DC source to the busbar.
b. Connect -12V DC negative to quick connect terminal
marked “Negative”.
c. Connect the positive side of each appliance to a switch
output terminal. Connect the negative side to DC negative.
4. To remove cover, apply heal of hand to label area and pull back on the cover edge.
Application Example
Connect adequate gauge supply
wire and circuit protection for
safe operation up to Panel
Cumulative Rating.
PN 4306 shown for
illustration purposes
VHF
BILGE PUMP
FISH FINDER
STEREO
HORN
GPS
EXAMPLE DEVICES
COMMON BUSBAR
FUSE
Legend
DC Positive
DC Negative
Optional: For dimming control of
label backlighting, remove
dimmer control wire from busbar
and connect to an electronic
Pulse Width Modulating dimmer
like Blue Sea Systems PN 7506.
CAUTION!
If 24-hour bilge
function is required, constant
power source must be considered.
Optional:ON-OFF Battery Switch
like Blue Sea Systems’ PN 6006 or
9003
e
.
5. Securely tighten toggle switch boots. Mount panel in cutout with provided
gaskets and screws. Insert fuse seal over fuses, ensure 2 seal ribs are
pressed in the panel. Reattach the cover.
COVER
FUSE SEAL
FUSES
CIRCUIT LABELS
GASKET
VOLTAGE LABEL
COVER
FUSE SEAL
TOGGLE
SWITCH
BOOTS
CUTOUT
WITH GASKET
AND SCREWS