Instructions for replacing valves and cleaning Series 62000 - 92000 LP Gas 501020
21
®
For assistance call 1.800.762.1142.
Instructions for replacing valves and cleaning Series 62000 - 92000 LP Gas 501020
22
®
For assistance call 1.800.762.1142.
Burner Connections
1. Make sure the regulator valve and hose connections are securely fastened to the burner
and the tank.
2. If your unit was assembled for you, visually check the connection between the burner
pipe and orifice. Make sure the burner pipe fits over the orifice.
WARNING: Failure to inspect this connection or follow these instructions could
cause a fire or an explosion which can cause death, serious bodily injury, or damage
to property.
3. Please refer to diagram for proper installation.
4. If the burner pipe does not rest flush to the orifice, please contact 1.800.762.1142 for
assistance.
Tank/Gas Line Connection
1. Make 2-3 oz. of leak solution by mixing one part liquid dishwashing soap with three parts
water.
2. Make sure control knobs are off.
3. Turn LP gas tank ON at valve.
4. Spoon leak check solution at all “x” and arrow locations.
5. If any bubbles appear turn LP gas tank OFF, reconnect and re-test. If you continue to see
bubbles after several attempts, disconnect LP gas source and contact 1.800.762.1142 for assistance.
6. If no bubbles appear after one minute turn tank OFF, wipe away solution and proceed.
X
X
X
X
X