Blue Rhino 22000 Series Owner'S Manual Download Page 1

Cleaning Instructions for 

Burner, Pilot Assembly, 

and Emitter Screen

Series: 220000 - 450000

Summary of Contents for 22000 Series

Page 1: ...Cleaning Instructions for Burner Pilot Assembly and Emitter Screen Series 220000 450000 ...

Page 2: ...with a hose Soft bristle brush Brass brush Heavy duty pipe cleaners Non abrasive Scouring Pad Rubber gloves Leak test solution 1 part liquid soap and 3 parts water 1 Installation and repairs should be done by a qualified service person 2 Use only Blue Rhino Global Sourcing Inc factory authorized parts The use of any other part that is not factory authorized can be dangerous and will void your warr...

Page 3: ... is soft to not scratch or damage any surface finishes When applicable tighten all hardware connections by hand first Once the step is completed go back and fully tighten all hardware while being cautious not to over tighten to avoid damaging surfaces or stripping hardware Follow all steps in order to properly assemble your product 2 Turn off heater per Turning Off instructions in owner s manual 3...

Page 4: ...Instructions for Burner Pilot Assembly and Emitter Screen Series 220000 450000 For assistance call 1 800 762 1142 Step 7 Remove emitter from emitter bottom by removing the 9 16 nut and flat washer from inside cone ...

Page 5: ...5 Cleaning Instructions for Burner Pilot Assembly and Emitter Screen Series 220000 450000 For assistance call 1 800 762 1142 Step 8 Remove the three bolts which secure the emitter to the emitter bottom ...

Page 6: ... Burner Pilot Assembly and Emitter Screen Series 220000 450000 For assistance call 1 800 762 1142 Step 9 Carefully separate the emitter from the emitter bottom Note Use caution not to loosen the burner stud spacer when separating ...

Page 7: ...ep 10 Clean the carbon build up off the inside of the emitter bottom with a non abrasive scouring pad or bottle brush Clean the outside of the emitter bottom with the scouring pad DANGER Never use any flammable solutions or material to clean heater or heater parts Use only a mild soap and water solution Do not to soak the valve ...

Page 8: ...8 Cleaning Instructions for Burner Pilot Assembly and Emitter Screen Series 220000 450000 For assistance call 1 800 762 1142 Step 11 Use a bottle brush to clean the inside of the emitter ...

Page 9: ...9 Cleaning Instructions for Burner Pilot Assembly and Emitter Screen Series 220000 450000 For assistance call 1 800 762 1142 Step 12 Blow out any excess soot with an air hose or a can of compressed air ...

Page 10: ...e the burner hold the burner supply tube nut in place with an 10 mm open end wrench to prevent it from moving At the same time using another 12 mm open end wrench unscrew the burner nut from the burner With the nut loose lift the burner out of the valve housing Use care not to damage the supply tube or any of the wires for the thermal couple ...

Page 11: ... Assembly and Emitter Screen Series 220000 450000 For assistance call 1 800 762 1142 Step 14 To remove the burner supply tube unscrew the brass nut which attaches the burner supply tube to the burner bracket Be careful not to damage the burner ...

Page 12: ...rner Pilot Assembly and Emitter Screen Series 220000 450000 For assistance call 1 800 762 1142 Step 15 Insert bottle brush into venturi tube and give a couple of twists This will clear any debris or spider webs from the venturi tube ...

Page 13: ...r Pilot Assembly and Emitter Screen Series 220000 450000 For assistance call 1 800 762 1142 Step 16 Insert a heavy duty pipe cleaner into each burner port to clean them Use a non abrasive scouring pad to clean the outside of the burner ...

Page 14: ...ons for Burner Pilot Assembly and Emitter Screen Series 220000 450000 For assistance call 1 800 762 1142 Step 17 Using an air hose or can of compressed air to blow any excess soot from the burner ports and the venturi tube ...

Page 15: ...ructions for Burner Pilot Assembly and Emitter Screen Series 220000 450000 For assistance call 1 800 762 1142 Step 18 Use a brush or compressed air to clean the burner orifice Use care not to enlarge the burner orifice ...

Page 16: ...tter Screen Series 220000 450000 For assistance call 1 800 762 1142 Step 19 Remove the copper pilot supply tube with a 10 mm open end wrench and a 12 mm open end wrench on the orifice nut With the pilot tube loose remove pilot tube Do not kink the copper tube ...

Page 17: ...ng Instructions for Burner Pilot Assembly and Emitter Screen Series 220000 450000 For assistance call 1 800 762 1142 Step 20 With pilot tube disconnected remove the 2 screws which secure the pilot to the bracket ...

Page 18: ...sistance call 1 800 762 1142 Step 21 With the pilot loose remove the pilot orifice This is done by securing the black hex tube with a 10mm open end wrench to prevent it from moving while using a 12mm open end wrench to remove the brass piece just below the black hex piece This is your pilot orifice ...

Page 19: ...19 Cleaning Instructions for Burner Pilot Assembly and Emitter Screen Series 220000 450000 For assistance call 1 800 762 1142 Step 22 Pilot orifice removed ...

Page 20: ...leaning Instructions for Burner Pilot Assembly and Emitter Screen Series 220000 450000 For assistance call 1 800 762 1142 Step 23 Use a pipe cleaner to clean both the inside and outside of the pilot orifice ...

Page 21: ...structions for Burner Pilot Assembly and Emitter Screen Series 220000 450000 For assistance call 1 800 762 1142 Step 24 With a brush lightly clean the top of the pilot orifice Use care not to enlarge the orifice hole ...

Page 22: ...Assembly and Emitter Screen Series 220000 450000 For assistance call 1 800 762 1142 Step 25 Use a heavy duty pipe cleaner to clean the bottom of the black hex tube on the pilot assembly Make sure to extend the pipe cleaner past the silver hood ...

Page 23: ...embly and Emitter Screen Series 220000 450000 For assistance call 1 800 762 1142 Step 26 1 Clean the port at the side of the pilot hood with a heavy duty pipe cleaner 2 Blow out any excess soot or debris with an air hose or a can of compressed air ...

Page 24: ...from the appliance and immediately call your gas supplier or your fire department WARNING FOR YOUR SAFETY You must follow all leak checking procedures before operating To prevent fire or explosion hazard when testing for a leak a Always perform leak test before lighting the heater and each time the tank is connected for use b No smoking Do not use or permit sources of ignition in the area while co...

Page 25: ...er pipe does not rest flush to the orifice please contact 1 800 762 1142 for assistance 30 Tank Gas Line Connection 1 Make 2 3 oz of leak solution by mixing one part liquid dishwashing soap with three parts water 2 Make sure control knob is in OFF position Figure 3 3 Turn LP gas tank valve to OPEN 4 Spoon leak check solution at all X locations Figures 1 and 2 a If any bubbles appear turn LP gas ta...

Page 26: ...ue Rhino Global Sourcing Inc Winston Salem NC 27040 1 800 762 1142 www BlueRhino com Blue Rhino Global Sourcing Inc Blue Rhino and It s not just propane are trademarks of Ferrellgas L P 22004500CI IS 103 ...