background image

04/21/03

SNX20AHJ

SNX20AHJ

SOLUTION

The release valve is not closed. 

Turn the valve clockwise tightly.

Low on hydraulic fluid. 

Refill the jack to the correct level of hydraulic

fluid.

Pump seals and back-up ring are defective.

Clean hydraulic fluid passages, replace seals and

renew hydraulic fluid.

(Must be serviced by qualified service center)

The hydraulic system is filled with air. Open

the release valve, pump handle rapidly (4) 

full strokes to purge air, close release valve.

Return spring is broken or linkages binding.

Replace spring if broken. Grease pivot shaft, 

oil all lift arm linkages.

Discharge ball is not sealing hydraulic system 

and oil may be dirty. Manually flush hydraulic 

system by raising and lowering lift arm by  

hand. Open the release valve, as required to   

raise and lower the lift arm. Manually raise   

and lower lift arm.

PROBLEM

Jack will not lift load

Jack will not hold load

or handle rises

Jack will not lift to

its full height

Jack will not lower

completely

Jack will not lift smoothly

or jack feels spongy