Summary of Contents for OX2500D Series

Page 1: ...E THIS MANUAL COMPLETELY AND COMPLY AS DIRECTED ALL THE POTENTIAL HAZARDS OF DUST AND MIST CONTROL SYSTEMS AND EQUIPMENT ARE IMPOSSIBLE TO LIST THEREFORE OBTAIN THE SERVICES OF A PROFESSIONAL INSTALLE...

Page 2: ...00D CFM Max 1800 with HEPA PSC Type H P Direct Drive with thermal overload 62 dBA Two Speed Switch 10 by 10 Direct Drive Centrifugal Forward Curve Louver with four way individually adjustable blades B...

Page 3: ...3 Installation of this unit in applications where there is a chance for heated and or flammable materials to enter the unit should be evaluated to determine if a fire protection extinguishing system...

Page 4: ...cal requirements you should follow the National requirements If the optional Drain Plug was installed in your unit you can connect an appropriate 3 8 I D rubber hose for oil mist routing All chains ho...

Page 5: ...ai n S wi n gi n g t o C eili n g R o of Tr uss O pti o n 2 M o u nti n g Str ut C h a n n el O X 2 5 0 0 I nst all ati o n M o u nti n g O pti o ns AI R F L O W 2 4 2 4 5 9 Str ut C h a n n el I nst...

Page 6: ...66 455 2135 blueoxaircleaners com Option 3 Wall Mounting with L Brackets Bolt Unit to L Bracket Lag Screw to Wall Stud Bolt with Spreader Nut if no Stud Block Wall Front Filter Side L Brackets should...

Page 7: ...ilter The reading may vary depending upon the contaminants Please consult your Sales Engineer for further information FILTERS All units are equipped with replaceable type media filters In some cases w...

Page 8: ...866 455 2135 blueoxaircleaners com info aircleaningspecialists com Blue Ox is a Product of Air Cleaning Specialists Inc OX2500D Wiring Diagram...

Page 9: ...866 455 2135 blueoxaircleaners com info aircleaningspecialists com Blue Ox is a Product of Air Cleaning Specialists Inc OX2500D with 3 speed Switch Wiring Diagram...

Page 10: ...24 X 24 X 4 Pre Filter Pleated MERV 8 9 BOF 4404 AM 24 X 24 X 4 Pre Filter Aluminum Mesh 10 BOF 443668 24 X 24 X 36 65 Bag Filter 8 Pocket 11 BOF 443698 24 X 24 X 36 95 Bag Filter 8 Pocket 12 BOF 4415...

Page 11: ...ion but not as required low or no airflow Check and open all dampers if installed Check ducting for blockage if installed Check for dirty or blocked filters refer to Maintenance section Check rotation...

Page 12: ...r Check heater rating against motor nameplate current rating Check motor load If the motor has manual re set thermal protector check if it has been tripped Motor may be overloaded Reduce load Increase...

Page 13: ...ring connections transformer Worn damaged dirty or overloaded bearings Replace check loading and alignment Loose or defective or out of balance air mover Tighten set screw s repair or replace Insuffic...