Installation of the earth (Drawing 1)
1 Pull the cable (
B
) through the strain relief (
F
) before fitting the synthetic strain relief (
F
) onto the earth bolt (
A
). Position the strain relief
(
F
) at approximately 10 cm from the eye (
H
) of the earth cable (
B
).
2 Place the eye (
H
) of the cable (
B
) onto the earth bolt (
A
) that is fitted to the housing.
3 Then place a toothed lock washer (
C
), a hexagon nut (
D
) and another toothed lock washer (
E
) on top of the eye (
H
).
4 Fit the strain relief (
F
) on top, creating a loop of Ø 5 cm.
5 Finally place the lock nut (
G
) onto the earth bolt (
A
).
6 Once the various nuts have been placed onto the earth bolt (
A
) in the correct sequence, they can be tightened with a spanner or a ring
spanner number 8. Do not tighten too firmly, otherwise you may crack the strain relief. (The transparent nut that was screwed on the earth
bolt (
A
) on delivery has no further use, and can be discarded).
Installation of the device (Drawing 2)
The Blue Lagoon UV-C Timer must never be installed behind the Ph regulator or the salt electrolysis system in your swimming pool
installation. The ideal location to install your device is behind the pump and the filter. Never submerge this device in water. The installation
must always take place outside of the pool. Ensure that there is always water flowing through the unit when the lamp is on.
1 Determine where the device will be installed. Make sure to leave a free area (+/- 1 metre) in order to be able to remove the lamp (
K
) /
quartz glass (
M
) for the purpose of replacement and/or maintenance.
2 Fit the supplied pipe clips (
O
) in fixed positions, press the unit into the pipe clips and tighten the three-part coupling (
I
). Pay hereby
attention to the correct position of the sealing rings (
P
), both with regard to the connections and the quartz glass (
see drawing 2
).
3 Fit the unit into the circuit using the three-part couplings (
I
). The inlet and outlet of the three-part coupling is Ø 63 mm. If your pipes are
smaller than 63 mm, you can use the adapter (Ø 63 x Ø 50 mm) (
T
). This must be glued onto the three-part coupling (
I
). On one side of the
adapter (
T
), there is a screw thread on the inside giving the option of fitting an adapter, with a sealing ring (not included in the delivery),
onto it if necessary. Adapter sets can be obtained from your distributor (article number B290020).
4 Unscrew the screw ring (
N
) from the housing (
U
). Remove the UV-C lamp (
K
) from the supplied case (see packaging) and carefully slide the
lamp into the quartz glass (
M
). Carefully connect the white lamp holder (
L
) to the UV-C lamp (
K
) and then screw the screw ring (
N
) hand-
tight onto the housing (
U
).
5 Activate the pump and check the flow and any leakage of the system.
6 Put the plug of the UV-C device in a wall socket with a safety ground and fitted with a residual current circuit-breaker. Check whether the
lamp is operating by looking through the transparent components of the unit. The unit is switched off by pulling the plug out of the socket.
Instructions for use of the digital time meter
As soon as the Blue Lagoon UV-C Timer is switched on, the program will carry out a self-test. The display will automatically show the
following , one after the other: 8888 (display test) ; r and software version number ; 50H or 60H indication of the mains frequency
Following this, the display will show the meter reading.
When the UVC lamp is switched on for the first time, or after the “reset” function has been used, the value ‘4500’ will appear on the display. A
dot next to the digit on the far right of the display will blink every second; this indicates that the counter is running.
The display is automatically set to the factory reading of 4,500 hours. The UV-C lamp operates at 100% radiation for up to 4,500 hours. After
4,500 hours, the radiation will weaken, and may become insufficient to obtain the desired results.
If the UV-C lamp had already been used previously, and is switched on again, the display will indicate the value it had at the time it was
switched off earlier. If you had increased or reduced the value of the time meter yourself, the display will indicate the latest counter reading it
had before it was switched off.
The settings of the time meter can be modified if you wish. This is carried out as follows:
After holding down the switch (
R
) underneath the display for 5 seconds, the display will show “rSt”, to indicate that the user menu has been
selected. Once the switch (
R
) has been released, the meter indication and “rSt” will blink alternately on the display. By briefly pressing the
switch again, it is now possible to step through the menu options. There are 3 available setting options in the menu: “
rSt
” “
UP
” and “
dn
”.
Summary of Contents for UV-C Timer
Page 1: ...1 The easy and friendly way to disinfect your pool Blue Lagoon UV C Timer 40 000 75 000 ...
Page 2: ...2 1 2 3 4 N M K R U J Q S O P P I L T ...
Page 75: ...75 1 2 3 4 N M K R U J Q S O P P I L T ...
Page 77: ...1 The easy and friendly way to disinfect your pool UV C TIMER 150 000 130 WATT AMALGAM ...
Page 78: ...2 1 2 3 4 N M K R U J Q S O P P I L T V W X ...
Page 143: ...67 1 2 3 4 N M K R U J Q S O P P I L T V W X ...