1. WARNING
• This product is intended for installation
by a qualified service person.
• Disconnect power at the service breaker
before installing or servicing.
• Failure to properly ground unit could
result in severe electrical shock.
2. NOTE
Do not install dryer over washbasin.
If the power supply cord is damaged, it
must be replaced by the manufacturer or its
service agent or a similar qualified person
in order to avoid a hazard. Means for
disconnection must be incorporated in the
fixed wiring in accordance with the current
wiring regulations.
PLEASE READ CAREFULLY THROUGH THIS MANUAL BEFORE USING
THE PRODUCT, OBSERVING ALL SAFETY INFORMATION, WARNINGS.
3. SPECIFICATION
Voltage:
220V-240V 50/60Hz, 8.2A, 2000W
110V-120V, 60Hz, 16.4A, 2000W
Air Temperature:
50°C (D=10CM, Room Temp.=25°C)
Air Velocity:
13M/S
Air Flow:
80M³/H
Drying Time:
35-40S
Sensor Range:
5-15CM
Protection Level:
IPX1
Electric Isolation:
CLASS 2
Brush Motor:
2300R/M
Noise(at 1M):
60dB
Cabinet Material:
ABS Plastic
4. INSTALLATION
1.
Installation must be carried out in
accordance with the current edition
of the local wiring regulations code
having jurisdiction. Installation should
be performed only by a qualified
electrician.
2.
Drill 4 mounting holes with Dia. 8mm
(5/16”) as the installation diagram size.
3.
Mount hand dryer back support on the
wall.
4.
Hang hand dryer on the back support
by pulling from up to down.
5.
Secure the dryer by the screw on hole
“A” to avoid theft.
6.
Connect the hand dryer plug to the
power supply. Connect wire as follows
if the dryer is ordered without plug:
A. Connect the live wire (Coloured
Brown or Red) to the terminal block
marked “L”.
B. Connect the neutral wire
(Coloured Black or Blue) to the terminal
block marked “N”.
5. OPERATION
•
No-touch operation.
•
Shake excess water from hands.
•
Place hands under the outlet to start
operation.
•
Rub hands lightly and rapidly.
•
Stops automatically after hands are
removed.
25
0M
M
230M
M
240M
M
65
M
M
17
M
M
8MM
A
22MM
INSTALL TEMPLATE
Back Hook
Heating
H
ea
tin
g
Motor
M
oto
r
Power
Relay
Transformer
Power
Motor
Blue
B
la
ck
B
la
ck
R
ed
Yellow
Heat Element
L
N
Blue
Brown
Terminal
Block
220 - 230V 50/60Hz
OR 110 - 120V 60Hz
Hand Dryer Main Circuit Board
Program Board
Sensor Board
Turn clockwise to
increase sensor range
Capacity