Troubleshooting Chart

Symptom

Possible Cause(s)

Corrective Action

Pump will not start or run

Pump starts and stops too
often

Pump shuts off and turns
on independently of
switch (trips thermal
overload protection)

Pump operates noisily or
vibrates excessively

Pump will not shut off

Pump operates but
delivers little or no water

1. Water level too low
2. Blown fuse or tripped circuit breaker
3. Low line voltage

4. Defective motor
5. Defective float switch
6. Impeller (pump filled with debris)
7. Tangled switch

8. Insufficient liquid level

1. Backflow of water from piping
2. Faulty float switch
3. Check valve not installed or leaking
4. Discharge head is less than

manufacturer's minimum

1. Excessive water temperature
2. Defective switch or entangled switch

is causing pump to run dry

3. Low line voltage

1. Worn bearings
2. Debris in impeller cavity or broken
3. Piping attachments to building

structure too rigid or too loose

1. Defective float switch
2. Float switch movement restricted

3. Restricted discharge (obstruction in

piping)

4. Excessive inflow or pump not

properly sized for application

1. Low line voltage

2. Debris caught in impeller or discharge
3. Worn or defective pump parts or

plugged impeller

4. Pump running backwards
5. Pump not properly sized for application
6. Check valve stuck closed or installed

backwards

7. Shut off valve closed

1. Pump switch will not turn on unless water covers top of pump
2. If blown, replace with proper sized fuse or reset breaker
3. If voltage is under recommended min i mum, check wiring size from

the main switch on property. If OK, contact power company.

4. Return for service or replace motor
5. Replace float switch
6. If impeller will not turn, remove volute and remove debris
7. Arrange switch so the switch moves free ly. Re po si tion pump if

necessary

8. Make sure liquid level is adequate

1. Install check valve
2. Replace float switch
3. Remove and examine check valve for prop er in stal la tion and free

operation

4. Recheck all sizing calculations to determine proper pump size

1. Pump should not be used for water above 120° 
2. Replace switch or reposition pump

Pump may start unexpectedly. Disconnect 
power supply before ser vic ing

3. If voltage is under recommended min i mum, check wiring size from

the main switch on property. If OK, contact power company

1. Return for service or replace
2. Remove housing, clean impeller and/or replace broken impeller
3. Replace portion of discharge pipe with flexible connector

1. Replace float switch
2. Reposition pump or clean basin as required to provide adequate

clearance for float switch

3. Remove pump and clean pump & piping
4. Recheck all sizing calculation to determine proper pump size

1. If voltage is under rec om mend ed minimum, check wiring size from

the main switch on prop er ty. If OK, contact power company

2. Remove, clean and check for tight ness
3. Replace worn parts or entire pump. Clean parts if required

4. Check rotation. (CCW from bottom) Return if CW
5. Recheck all sizing calculations to determine proper pump size
6. Remove and examine check valve for proper installation and free

operation

7. Open valve

Please provide following

information:

- Model number
- Serial number (if any)
- Part description and number as

shown in parts list

Address parts 
correspondence to:

Blue Angel Pumps
10 Production Drive
Harrison, OH  45030  U.S.A.

1

1/4” NPT Plug

16356-004

1

2

Power Cord-10 ft. (BEF50T, BEF75T)

31035-001

1

Power Cord-20 ft. (BEF50T-2, BEF75T-2)

31036-001

1

3

Handle

23124

1

4

Motor Housing

41026-001

1

5

O-ring

19040-001

1

6

Motor Assembly

*

63004-001

1

7

Impeller

41032-001

1

8

Volute

41028-001

1

9

Mechanical Switch (BEF50T, BEF75T)

30000-009

1

Mechanical Switch (BEF50T-2, BEF75T-2) 30000-003

10

Vertical mechanical switch with 
10’ power cord

63005-001

1

7/16”-14 x 1-1/4” Hex Head Screw

**

3

5/16”-18 x 3/4” Hex Head Screw

**

3

10-24 x 1/2” Round Head 
Machine Screw

**

2

*

Includes Motor, Seal Plate, Shaft Seal, and O-ring

**

Standard Hardware Item

Ref 
No.

Description

Part. No.

Qty.

www.blueangelpumps.com

1

2

3

4

5

6

7

8

For Replacement Parts, call 1-888-636-6628

9

10

Summary of Contents for BEF50M

Page 1: ...ds compatible with pump component materials Failure to follow this warning can result in personal injury and or property damage 2 Make certain that the power source electric motor conforms to the requirements of the equipment Disconnect power before servicing If the power dis connect is out of sight lock in the open position and tag it to prevent unexpected application of power Failure to do so co...

Page 2: ...g wall receptacle is encountered it must be replaced with a properly grounded 3 prong receptacle installed in accordance with the NEC and local codes and ordinances 12 All wiring should be performed by a qualified electrician 13 Always connect this product to a grounded outlet equipped with a Ground Fault Circuit Interrupter GFCI 2 Operating Instructions and Parts Manual Installation In any instal...

Page 3: ...anty For three years from the date of purchase Blue Angel will repair or replace at its option for the original purchaser any part or parts of its Sump Pumps or Water Pumps Product found upon examination by Blue Angel to be defective in materials or workmanship Please call Blue Angel 888 636 6628 for instructions or see your dealer Be prepared to provide the model number when exercising this warra...

Page 4: ...or proper installation and free operation 4 Recheck all sizing calculations to determine proper pump size 1 Pump should not be used for water above 120 2 Replace switch or reposition pump Pump may start unexpectedly Disconnect power supply before servicing 3 If voltage is under recommended minimum check wiring size from the main switch on property If OK contact power company 1 Return for service o...