background image

Installation

(Cont.)

The length of the tether (distance
of cord from float to clamp) should
not be set shorter than 3-1/4 inches
and should not be used in a basin
smaller than 14 inches in diameter.
If factory setting is changed, be sure
when the pump shuts off at least 4”
of fluid is left in the basin so the
impeller remains submerged.

7. When a tether switch is used, rigid

discharge pipe is required. If the
pump is allowed to move, the
tether switch could be restricted by
the basin wall, preventing the
pump from operating.

Before

removing

pump from basin for service, always
disconnect electrical power to pump
and control switch. For any work on
pump or switch, ALWAYS unplug the
power cord. Do not just turn off circuit
breaker or unscrew fuse.

Maintenance

Make

certain

that the pump is unplugged before
attempting to service or remove any
component. This pump is assembled in
the factory using special equipment;
therefore only authorized service
dealers or qualified electricians should
attempt to repair this unit. Improper
repair can cause an electrical shock
hazard.

The pump
contains

oil that may be under pressure because
of heat. Let the pump cool for a
minimum of two hours before servicing
this unit.

1. Disassembly of the motor prior to

expiration of warranty will void the
warranty. It might also cause
internal leakage and damage to the
unit. If repairs are required, return
the pump to the dealer from whom
it was purchased or call 
1-888-636-6628. If motor is ever
disassembled the seals must be
replaced. Care must be taken to
ensure that all seals do not leak.

2. After the basin cover is removed

and necessary discharge piping
disconnected, lift pump from basin.

3. Pump should be checked on a

regular basis for proper operation.
If anything has changed since unit
was new, the unit should be
removed and repaired or replaced.
Only qualified electricians or service
people should attempt to repair this
unit. Improper repair and/or
assembly can cause an electrical
shock hazard.

4. Place the pump in a suitable area

where it can be cleaned thoroughly.
Remove all scale and deposits on
pump.

5. Submerge the complete pump in a

disinfectant solution (10% chlorine
bleach solution) for at least one
hour before handling the pump.

6. Clean all dirt and deposits from the

pump float. Make sure float moves
freely after cleaning.

7. Clean all dirt and deposits away

from pump inlet and volute.

This

pump

contains dielectric motor oil for
lubrication and motor heat transfer.
This oil can be harmful to the
environment. Check state laws before
disposing of this oil. This oil can be
harmful to aquatic life so consideration
should be exercised in the application
of this pump.

www.blueangelpumps.com

BALE Series

Limited Warranty

For two (2) years from the date of purchase, Blue Angel will repair or replace, at its option, for the original purchaser
any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Blue Angel to be defective
in materials or workmanship. Please call Blue Angel (888-636-6628) for instructions or see your dealer. Be prepared to
provide the model number when exercising this warranty. All transportation charges on Products or parts submitted for
repair or replacement must be paid by purchaser.
This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect,
improper installation, improper maintenance, or failure to operate in accordance with Blue Angel’s written instructions.

THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO TWO YEARS FROM THE DATE OF PURCHASE. THIS
IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAMAGES
OR EXPENSES WHATSOEVER IS EXCLUDED.

Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or
limitations of incidental or consequential damages, so the above limitations might not apply to you. This limited war-
ranty gives you specific legal rights, and you may also have other legal rights which vary from state to state.
In no event, whether as a result of breach of contract warranty, tort (including negligence) or otherwise, shall Blue
Angel or its suppliers be liable for any special, consequential, incidental or penal damages including, but not limited to
loss of profit or revenues, loss of use of the products or any associated equipment, damage to associated equipment,
cost of capital, cost of substitute products, facilities, services or replacement power, downtime costs, or claims of buyer’s
customers for such damages.
You 

MUST

retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you

MUST 

send a 

copy

of the purchase receipt along with the material or correspondence. Please call Blue Angel (888-636-

6628) for return authorization and instructions.

DO NOT MAIL THIS FORM TO BLUE ANGEL. 

Use this form only to maintain your records.

MODEL NO._______________ SERIAL NO.__________________________ INSTALLATION DATE_____________

ATTACH YOUR RECEIPT HERE

3

Reviews: