8
/
27
2.1.2.2 Maintenance Procedures of the Transmitting Part
(
NO launch
)
Connect the PC and the phone with maintenance line,
then making the phone into the RF state with META software
Check
Transceiver
to
see if IO signals exist.
Check the
PA output
to
see if there is RF signal
Y
Check
CPU
N
Check RF coaxial
switch or matching
network.
Y
Check
the
Transceiver
to see if
there is RF signal
N
CheckVBAT,PA_EN,
BANDSW_DCS,VAP
Replace
PA
Y
Check CPU
Y
Check
Transceiver if LE
、
SCLK/SDAT
、
RFVCOEN
、
VCXOEN have the
correct signal
.
N
N
N
N
Y
Replace
Transceiver