No Cold Water dispensing
1) Check main water supply line is on at source
and water is flowing into rear of system.
2) Cold tank water may have been exhausted and
drained by too much use and not had enough time
to recover. Mostly true on RO systems. Check
incoming flow at top of tank lid.
3) Check main solenoid is plugged in at ICB and
operating. Solenoid is at point of entry on lower
left back side.
5) Filter clog. Check water lines “in and out” of
each filter until water is no longer flowing. This
reveals which filter has clogged.
Water is NOT cold
1)
Check COLD control is turned to left (colder
setting) near top rear of system. Right side.
Use flat screw driver tip.
2)
Water level may have been drained and
exhausted by over use and not had enough to
chill new incoming water.
3)
Compressor relay may have failed. Replace
with spare relay from parts dept. to confirm.
4)
Check compressor if it is running continuously
and feels extremely hot to touch. If so, system
is low on coolant and needs to be recharged
with R-134A refrigerant.