2013-07
1 866 907 0122 blubathworks.com
®
3
MAINTENANCE
Cartridge Change
To replace:.
•
Shut off water supply to both inlets
•
Remove the control lever (1), remove the grub screw (2), take off the control handle (3) and pull out the
cup (4).
•
Pay attention not to lose the O-ring (5).
•
Unscrew the flange (6) using 30mm/1
1
/
16
”
spanner. Remove the cartridge (7).
•
Before re-assembling cartridge (7) clean its housing with wet cloth.
•
Re-assembling the flange (6) and the O-ring (5).
•
Re-fit the cup (4).
•
Re-fit the control knob (3) and fix it with the grub screw (2).
•
Re-fit the lever (1).