Cartridge Change

To replace:.
• 

Shut off water supply to both inlets

• 

Remove the control lever (1), remove the grub screw (2), take off the control handle (3) and pull out the 
cup (4).

• 

Pay attention not to lose the O-ring (5).

• 

Unscrew the flange (6) using 30mm/1

1

/

16

 

spanner. Remove the cartridge (7).

• 

Before re-assembling cartridge (7) clean its housing with wet cloth.

• 

Re-assembling the flange (6) and the O-ring (5).

• 

Re-fit the cup (4).

• 

Re-fit the control knob (3) and fix it with the grub screw (2).

• 

Re-fit  the lever (1).

   

   

   