Bloomfield H-336 Operation Manual Download Page 6

INSTALLATION 

NOTE:

  DO NOT discard 

the carton or other packing 
materials until you have 
inspected the appliance for 
hidden damage and tested it 
for proper operation. 
Refer to 

SHIPPING DAMAGE 

CLAIM PROCEDURE 

on the 

inside front cover of this 
manual. 

 

IMPORTANT: 

Water damage caused by 
failure to seat Wellsloks or 
failure to install gasket or to 
seal flange to counter is NOT 
covered by warranty 
 
 

IMPORTANT: 

Contact a licensed electrician 
to install and connect electrical 
power to the hotplate. 
 

IMPORTANT: 

Damage due to being 
connected to the wrong voltage 
or phase is NOT covered by 
Warranty. 

UNPACKING & INSPECTION

 

 

Carefully remove the hotplate from the carton. Remove all  
protective plastic film, packing materials and accessories from the 
hotplate before connecting the hotplate to electrical power or other-
wise performing any installation procedure.

 

 

Carefully read all instructions in this manual and the 

Installation 

Instruction Sheet

 packed with the hotplate before starting any 

installation.

 

 

Read and understand all labels and diagrams attached to the 
hotplate.

 

 

Carefully account for all components and accessories before 
discarding packing materials. Store all accessories in a convenient 
place for later use. 
 

PREPARATION

 

 

Carefully the 

Installation Instruction Sheet

 packed with the hotplate for 

cutout dimensions and restrictions.  

 

Hotplate must be installed in a metal counter only. 

 

Supplied gasket must be installed under the mounting flange, and the 
Wellsloks turned out to seal the hotplate and control unit to the 
counter. 

 

Apply a thin bead of food-grade silicone sealant where the flange 
meets the counter. 
 

ELECTRICAL 

 

Hotplate must be installed by a licensed electrician in accordance with 
all applicable codes and ordinances.

 

 

Refer to the nameplate. Verify the electrical service power. Voltage 
and phase must match the nameplate specifications. Connecting  the 
hotplate to the wrong voltage can severely damage the equipment or 
cause noticeably decreased performance. 

 

The ground lug of the hotplate and control unit must be connected to 
a suitable building ground.  
 

INSTALLATION NOTE:

  The installation of          units requires 

additional evaluations to Underwriters Laboratory standards. 
 
 

222 

 p/n

 3037

34 
  

OpM

anual Built-In

 Hotplate

BOTT

OM

OF COUNTER

Summary of Contents for H-336

Page 1: ... or to the person responsible for TRAINING OPERATORS of this appliance Additional manuals are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Contact your WELLS DEALER if you have any questions concerning installation operation or maintenance of this equipment OPERATION MANUAL for BUILT IN ELECTRIC HOTPLATES Models H 336 H ...

Page 2: ...he note of loss or damage is signed by the delivery person 2 FILE CLAIM FOR DAMAGE IMMEDIATELY Regardless of the extent of the damage 3 CONCEALED LOSS OR DAMAGE if damage is unnoticed until the merchandise is unpacked notify the transportation company or carrier immediately and file CONCEALED DAMAGE claim with them This should be done within fifteen 15 days from the date the delivery was made to y...

Page 3: ...06 Dual 9 208 V 1ø 14 4 A 3 0 kW 14 3 4 W x 23 1 2 D french plates 240 V 1ø 16 7 A 4 0 kW Refer to Installation Instructions for cutout dimensions Thank You for purchasing this Wells Bloomfield appliance Proper installation professional operation and consistent maintenance of this equipment will ensure that it gives you the very best performance and a long economical service life This manual conta...

Page 4: ...lslok Mounts hotplate unit to counter CONTROL UNIT Temperature Control Infinite switch to control temperature of heating element Indicator Light Glows any time temperature control is on Name Plate Lists manufacturer model number and serial number Also lists voltage and wattage rating not used on model H 706 FEATURES OPERATING CONTROLS HEATING ELEMENT WELLSLOK HOTPLATE UNIT CONTROL UNIT ELEMENT SUP...

Page 5: ... considered to be a permanent part of the appliance This manual and all supplied instructions diagrams schematics parts breakdown illustrations notices and labels must remain with the appliance if it is sold or moved to another location This appliance is made in the USA Unless otherwise noted this appliance has American sizes on all hardware This appliance conforms to NSF Standard 4 for sanitation...

Page 6: ... diagrams attached to the hotplate Carefully account for all components and accessories before discarding packing materials Store all accessories in a convenient place for later use PREPARATION Carefully the Installation Instruction Sheet packed with the hotplate for cutout dimensions and restrictions Hotplate must be installed in a metal counter only Supplied gasket must be installed under the mo...

Page 7: ...re control is on Cooking Recommendations Save energy by turning the temperature control off any time the hotplate is not in use The coil type heating elements will provide full heat within 30 seconds while french plate heating elements will reach full heat within 2 minutes making it unnecessary to leave the unit on during intermittent use Each heating element can hold up to a 16 quart pot or pan F...

Page 8: ...trical power and allow heating elements to cool completely before cleaning COILED HEATING ELEMENTS Lift coiled heating elements and remove drip pans Clean drip pans with a plastic spatula or plastic scouring pad mild detergent and warm water DO NOT use metal implements steel wool or metal scouring pads to clean drip pans Rinse drip pans by wiping with a clean cloth or sponge dampened with clean wa...

Page 9: ...ement or other internal component SUGGESTED REMEDY Turn disconnect ON Check reset circuit breaker Turn temperature control to desired setting Contact Authorized Wells Service Agency for repairs Adjust for desired temperature Be sure supply voltage matches nameplate voltage Contact Authorized Wells Service Agency for repairs NOTE There are no user serviceable components in this appliance In all cas...

Page 10: ...222 p n 303734 OpManual Built In Hotplates NOTES 8 ...

Page 11: ...__________ VOLTAGE check one 120 208 240 DESCRIPTION SERVICE PART NO Drip Tray 8 for H 636 21705 Element Support H 636 H 656 500039 PARTS SERVICE 222 p n 303734 OpManual Built In Hotplates 9 IMPORTANT Use only factory authorized service parts and replacement filters For factory authorized service or to order factory authorized replacement parts contact your Wells authorized service agency or call ...

Page 12: ...TION CUSTOMER SATISFACTION Commercial Food Equipment Service Association Wells Bloomfield proudly supports CFESA Commercial Food Equipment Service Association PRINTED IN UNITED STATES OF AMERICA WELLS BLOOMFIELD LLC 2 ERIK CIRCLE P O Box 280 Verdi NV 89439 www wellsbloomfield com telephone 775 689 5703 fax 775 689 5976 ...

Reviews: