SERVICING INSTRUCTIONS (continued) 

13 

REPLACE HEATING ELEMENT 

 
Remove tank lid assembly per above. 

 
Remove two hex nuts holding element to cover.  Pull element 
from mounting holes. 

 
Reassemble in reverse order. 
 

REPLACE WARMER ELEMENT 

 

Remove warmer plate by turning counter-clockwise. 

 
Lift element from bracket. Disconnect wiring. 

 

Reassemble in reverse order.

 

 
REPLACE SOLENOID 

 

Symptom:  brewer will not flow water; or, brewer drips              
continuously from brew head.) 

 

Unplug power cord or turn circuit breaker 

OFF

.  Turn 

OFF

 and 

disconnect water supply from brewer inlet fitting. 

 
Remove water bottle and top panel. 

 
Cut tie straps from solenoid hose connections.  Remove wiring 
connections from solenoid coil.  Remove solenoid 

 
Reassemble in reverse order. 

 

REPLACE TIMER ASSEMBLY 

 

Unplug power cord or turn circuit breaker OFF. 

 
Remove front panel.  Remove knob and three screws holding 
timer to bracket.  Disconnect wiring to timer. 

 
Reassemble in reverse order. 
Adjust timer as described on page 12. 
 

REPLACE BREW READY LIGHT, BREW SWITCH  OR 
WARMER SWITCH 

 
Unplug power cord or turn circuit breaker OFF. 

 
Remove water bottle, top panel and basin pan. 

 
Using Switch Removal Tool (p/n 

83209)

 or a thin screwdriver, pry 

light or switch from mounting hole.  Disconnect leads. 

 
Reassemble in reverse order. 

IMPORTANT:  

When replacing 

heating element, also replace 
seal gaskets. 
 
 

Summary of Contents for Aquarius 8372EU

Page 1: ...M681EU 040913 cps 681EU OWNERS MANUAL for BOTTLED WATER DECANTER COFFEE BREWERS MODEL 8372EU for 3 Gallon and 5 Gallon Plastic Bottles Includes Installation Operation Use Care Servicing Instructions M...

Page 2: ...ninety 90 days from date of purchase on non warranted equipment Any use of non genuine Bloomfield parts completely voids any warranty 11 Installation labor and job check out are not considered warrant...

Page 3: ...care for and maintain or repair the appliance in a manner which will ensure its optimum performance WARRANTY STATEMENT xi SPECIFICATIONS 1 FEATURES OPERATING CONTROLS 2 PRECAUTIONS GENERAL INFORMATION...

Page 4: ...FEATURES AND OPERATING CONTROLS 2 Fig 1 Features Operating Controls...

Page 5: ...liance use limitations and associated hazards Operating instructions and warnings must be read and understood by all operators and users Except as noted this piece of equipment is made in the USA and...

Page 6: ...del 8372EU is equipped with a cord and plug It requires a 220 240 volt 10 amp circuit 50 Hz 2 wire plus ground with CEE 7 7 Receptacle IMPORTANT Supply power must match nameplate for voltage and phase...

Page 7: ...equate amount of water in place will produce very little or no brewed coffee IMPORTANT When installing water bottle be careful to not overflow the basin pan DO NOT fill the basin pan prior to installi...

Page 8: ...IC OPERATION Water is supplied to the hot water tank by a bottle inserted in the bottle ring Water will flow from the bottle into the basin pan until the water level reached the open mouth of the bott...

Page 9: ...ng a brew may lower the temperature of the brew water PREPARATION Place one 1 genuine Bloomfield paper filter in the brew chamber Add a pre measured amount of fresh coffee grounds Gently shake the bre...

Page 10: ...ed to clear clogged spray holes Rinse the spray disk with clean water and allow to air dry 7 Wash the brew chamber in a sink using warm water and a mild detergent A bristle brush may be used to clean...

Page 11: ...brewer 7 Wash the basin pan and bottle ring with a clean cloth and mild detergent 7 Soak the basin pan basin seal and top panel in sanitizer per the directions supplied with the sanitizer 8 Rinse the...

Page 12: ...SIBLE CAUSE Brewer unplugged or circuit breaker tripped Thermostat set too low Hi Limit thermostat tripped Damaged internal component or wiring Water bottle empty Too much coffee grounds Timer out of...

Page 13: ...sed on altitude Upon completion reinstall top panel CAUTION Electric Shock Hazard Opening access panels or removing warmer plates on this brew may expose uninsulated electrical components Disconnect b...

Page 14: ...er bottle Run water from the hot water faucet until no more water flows Remove top panel Siphon water from the tank through the faucet supply fitting until the water level in the tank is below the tan...

Page 15: ...ove water bottle and top panel Cut tie straps from solenoid hose connections Remove wiring connections from solenoid coil Remove solenoid Reassemble in reverse order REPLACE TIMER ASSEMBLY Unplug powe...

Page 16: ...Brush Large Sink or other appropriate work area 1 Disconnect brewer from the electrical supply Remove the water bottle and drain the tank by running water from the hot water faucet until no more wate...

Page 17: ...Verify that all internal components are dry then reinstall the top panel 10 Reconnect brewer to electrical supply 11 Install the brew chamber without filter paper or grounds Run at least three full b...

Page 18: ...STRICTOR BREW NOZZLE 1 41 83384 TUBE FAUCET SUPPLY METAL 1 42 85609 INSERT BREW OUTLET ELBOW 1 43 82241 FITTING BARBED BRASS 1 45 84619 SOLENOID BREW 240V 1 46 85634 TUBE BREW SILICONE 1 54 8043 12 GA...

Page 19: ...3 31 85646 SWITCH BREW MOMENTARY 250V 1 32 8738 2 INDICATOR LIGHT GREEN 240V 1 35 82748 TIMER 8 MIN 1 36 8889 1 POWER CORD EURO 1 37 35 212 STRAIN RELIEF 1 45 84619 SOLENOID BREW 220 240V 1 50 86280 T...

Page 20: ...LABEL 1 90 8706 76 BUTTON PLUG 1 1 8 3 8372CA 91 18 50 NUT WARMER PLATE RETAINING 1 4 28 3 8372CA 101 BASE BODY ASSEMBLY 1 102 BASE LOWER FRONT PANEL 1 103 BASE UPPER FRONT PANEL 1 104 BASE DOOR 1 10...

Page 21: ...WIRING DIAGRAM 19...

Page 22: ...c Division of Carrier Commercial Refrigeration In US and Canada Telephone 775 689 5700 Fax 888 492 2783 Fax 800 356 5142 website www wellsbloomfield com for orders only Bloomfield Industries proudly s...

Reviews: