SERVICING INSTRUCTIONS (continued)
15
CAUTION:
SHOCK HAZARD
Disconnect brewer from electric
power before opening the top
panel.
The brewer is shipped from the
factory pre-set for 25% bypass.
This adjustment must never be
made unless the brewer is
installed on a soft water line, or
a change in coffee strength is
required.
Bypass Gauge Set
Bypass Adjustment
BYPASS ADJUSTMENT (9104A ONLY)
PRECAUTIONS: Disconnect brewer from electric power.
Allow brewer to cool.
FREQUENCY: As required to adjust for change in delivered
volume, or to taste.
TOOLS: Phillips head screwdriver
Stubby flathead screwdriver
Provided wire gauge set
1. Press TANK HEATER switch to
OFF.
Disconnect brewer
from electrical power.
2. Remove SATELLITE, BREW CHAMBER, TOP PANEL and
BASIN.
3. Turn bypass adjustment screw several turns counter-
clockwise. Insert and hold appropriate gauge fully into
bypass valve from the outside of the brewer.
4. Turn bypass adjustment screw clockwise until the resistance
of the adjuster contacting the gauge is felt.
5. Release the gauge set. Turn bypass adjustment screw
counterclockwise slowly until gauge set fall out of the valve.
6. Reassemble brewer and perform a 1 gallon brew and sample
for taste. Adjust from this point to achieve desired taste:
a. Repeat steps 1 and 2.
b. Turn bypass adjustment screw counterclockwise to
decrease coffee strength (increase dilution); or ,
clockwise to increase coffee strength (decrease dilution).
7. Perform BREW TIMER ADJUSTMENT to insure delivery of
128 oz. in 1 gallon mode.
Procedure is complete
663