SERVICING INSTRUCTIONS (continued)
AUTION:
HOCK HAZARD
Disconnect brewer from electric
power before opening the
DFFHVVSDQHO
$GMXVWPHQWVWREHSHUIRUPHGE\
TXDOL¿HGWHFKQLFLDQRQO\
127(
%UHZHULVSUHDGMXVWHGWRGHOLYHU
DQGJDOORQVRIFRIIHHDW
DZDWHUSUHVVXUHRISVL
8VHWKLVSURFHGXUHWRDGMXVWWKH
GHOLYHUHGYROXPHWRVXLWORFDO
FRQGLWLRQV
TIMER ADJUSTMENT
35(&$87,216 'LVFRQQHFWEUHZHUIURPHOHFWULFSRZHU
$OORZEUHZHUWRFRRO
)5(48(1&<
$VUHTXLUHGWRDGMXVWGHOLYHUHGYROXPH
722/6
3KLOOLSVKHDGVFUHZGULYHU
Server or other container to calibrate volume
3UHVV+($7(5212))VZLWFKWR
OFF.
Turn POWER switch on back of brewer
OFF.
5HPRYH7233$1(/2SHUDWLQJFRQWUROVDUHDFFHVVLEOH
WKURXJKWKHWRSSDQHORQO\
$GMXVWWKH7,0(5VHWWLQJ
NOTE:
(DFKVLGHKDVLWVRZQWLPHU7KH/()77,0(5LVIRU
WKH/()76,'(WKH5,*+77,0(5LVIRUWKH5,*+76,'(
Turn
CLOCKWISE
to increase time;
E
Turn
COUNTER-CLOCKWISE
WRGHFUHDVHWLPH
$GMXVWRQO\LQVPDOOLQFUHPHQWVWRDYRLGODUJHYROXPH
YDULDWLRQV5HFRPPHQGQRPRUHWKDQWXUQ
5HSODFH7233$1(/7XUQ32:(5VZLWFK
ON.
Press HEATER ON/OFF switch to
ON.
$OORZWKHEUHZHUWRFRPHXSWREUHZLQJWHPSHUDWXUHWKHQ
SHUIRUPDWHVWEUHZ&KHFNGHOLYHUHGYROXPH
5HDGMXVWDVQHFHVVDU\
:KHQGHVLUHGYROXPHLVDFKLHYHGSURFHGXUHLVFRPSOHWH
14
SECONDS
1/16 TURN
MAXIMUM
500
187
IL2550
7
3
1 2M-Z1
6
47
8
O
wners Manual
8
7
90
Thermal Brewer