- 14 -
Step 3. Press the green bottom to select
“AUTO” position.
Step 4. The four button / LED display interface allows continuous monitoring of
sensor values, as well as for quick changes to LOW and HIGH setpoints.
Refer to the operating manual for more details in how to operate controller.
WARNING:
Do not use isolation valves to throttle the pump. This may cause
loss of prime, excessive temperature, and damage of the pump, voiding
warranty.
Step 5. Check piping for visible leaks. If your BLOOM pump is equipped with a pump
strainer, verify through the clear window in the strainer lid that there are no bubbles
entering in through the liquid suction stream.
A large air pocket or large bubbles should not be visible in the strainer basket. If large
bubbles or an air pocket is visible in the strainer basket there is a suction pipe leak.
Turn OFF BLOOM and check suction pipe for leaks and ensure all pipe connections
are airtight.
Refer to the BLOOM Manual to configure the operational mode of the BLOOM.